TS EN 12464 Periodic Inspection of Lighting

Compliant with regulations.

Our reports have international validity; they comply with both national legislation and... TS EN 12464 workplace lighting standard It fully meets the requirements.

AES Innovation

Lighting Periodic Inspection: TS EN 12464 Compliant Inspection Service

Inadequate in the workplace. lighting periodic inspection This practice threatens both employee health and opens the door to serious legal consequences. In Türkiye, the Work Equipment Regulation and... TS EN 12464 The standard mandates that all employers have their lighting installations inspected at regular intervals.


Lighting control, This is the process of verifying the technical adequacy and legal compliance of all lighting systems in a workplace—including general, local, emergency, and safety lighting—through on-site measurements. The process is carried out using a calibrated luxmeter. lighting measurement, This includes glare (UGR) control, color rendering evaluation, and circuit integrity inspection. The output of the process is a formally valid report. lighting periodic inspection reportStop.

What is Periodic Lighting Inspection?

TS EN 12464: Workplace Lighting Standard

TS EN 12464 workplace lighting standard, The system classifies work environments according to their area of responsibility, determining the minimum illumination level (lux), maximum glare index (UGR), and minimum color rendering index (Ra) for each area. According to the standard, values of 500 lux and above are mandatory for office desks, 100 lux for corridors and passageways, and 750 lux and above for sensitive assembly lines. Lighting measurement involves verifying all these parameters in the field using calibrated devices.

WHY AES INNOVATION?

Scope of Periodic Inspection of Industrial Lighting

Industrial lighting periodic inspection It has a very broad scope. Production areas, warehouses, laboratories, offices, stairwells, open spaces, and explosive environments (Ex-proof zones) are included in this inspection process. Measurement points specific to each area are determined, light distribution maps are created, and existing values are compared with standard limit values. If deviations are detected, corrective action recommendations are also added to the report.

AES Innovation

Contents of the Lighting Periodic Inspection Report

A technically valid lighting periodic inspection report; The measurement point plan must include lux and UGR values for each point, a TS EN 12464 limit comparison table, non-conformity findings, and accreditation information. AES Innovation reports, prepared with TÜRKAK-approved calibration certificates and the inspector's signature, serve as legal documents in Ministry of Labor and Social Security audits, Social Security Institution inspections, and insurance processes.

Frequently Asked Questions

According to the Work Equipment Regulation, this must be done at least once a year. Monthly short tests and annual full tests are also required for emergency lighting systems.

It covers all indoor work environments, including industry, offices, healthcare, education, and commerce. For outdoor work areas, TS EN 12464-2 applies.

Illuminance level (lux), glare index (UGR), color rendering index (Ra), and luminaire operational continuity measurements are performed.

Depending on the size of the facility, an electrical internal installation inspection in an average business is completed within 1-3 days. This period may be longer in extensive industrial facilities.

At AES Innovation, we deliver the report within 5 business days of the field measurement.

No. Measurements can be scheduled outside of or between production shifts; a flexible schedule is applied according to the facility's operating procedures.

TURKAK accreditation guarantees that tests and measurements are performed using reliable and repeatable methods in accordance with international standards. Reports issued by accredited laboratories have legal validity.