{"id":6431,"date":"2026-10-12T13:51:09","date_gmt":"2026-10-12T10:51:09","guid":{"rendered":"https:\/\/aesinn.com\/zpkr04-yangin-algilama-ve-uyari-sistemleri-periyodik-kontrol-raporu-ve-kriterleri\/"},"modified":"2026-10-12T13:51:09","modified_gmt":"2026-10-12T10:51:09","slug":"zpkr04-yangin-algilama-ve-uyari-sistemleri-periyodik-kontrol-raporu-ve-kriterleri","status":"publish","type":"post","link":"https:\/\/aesinn.com\/en\/zpkr04-yangin-algilama-ve-uyari-sistemleri-periyodik-kontrol-raporu-ve-kriterleri\/","title":{"rendered":"Fire Detection and Warning Systems Periodic Inspection Report (ZPKR04) and Criteria (ZPKK04): Ministry Format"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u00c7al\u0131\u015fma ve Sosyal G\u00fcvenlik Bakanl\u0131\u011f\u0131, <strong>yang\u0131n alg\u0131lama ve uyar\u0131 sistemleri<\/strong> periyodik kontrolleri i\u00e7in zorunlu bir rapor format\u0131 (<strong>ZPKR04<\/strong>) ve kontrol kriterleri dok\u00fcman\u0131 (<strong>ZPKK04<\/strong>) yay\u0131mlad\u0131. Dok\u00fcmanlar 18.07.2025 tarihinde yay\u0131mland\u0131; <strong>01.09.2025<\/strong> tarihinden itibaren bu format\u0131n \u015feklen ve i\u00e7erik olarak eksiksiz kullan\u0131lmas\u0131 zorunludur. Format, \u0130\u015f Ekipmanlar\u0131 Y\u00f6netmeli\u011fi&#8217;nin 14\/B maddesine dayan\u0131r; ana ba\u015fl\u0131klar ve s\u0131ralar\u0131 de\u011fi\u015ftirilmeden, i\u00e7eriklerin boyut ve yerle\u015fimi uyarlanarak kullan\u0131labilir. Bu sayfa, kriterlerin neyi arad\u0131\u011f\u0131n\u0131 ve raporun hangi b\u00f6l\u00fcmlerden olu\u015ftu\u011funu dok\u00fcmanlara dayanarak \u00f6zetler.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kapsam ve rapor d\u00fczenleme kurallar\u0131<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Bu dok\u00fcman Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik kapsam\u0131ndaki yap\u0131lar\u0131n, yang\u0131n alg\u0131lama ve uyar\u0131, acil ayd\u0131nlatma ve y\u00f6nlendirme sistemi ekipmanlar\u0131n\u0131n periyodik kontrollerini kapsar.<\/li><li>Kontrol raporu her bir yang\u0131n kontrol paneli b\u00f6lgesi i\u00e7in ayr\u0131 ayr\u0131 d\u00fczenlenmelidir.<\/li><li>Raporun eki olarak uygunsuzluk bulgular\u0131 foto\u011fraf ile g\u00f6sterilebilir.<\/li><li>Yang\u0131n alg\u0131lama, uyar\u0131, acil ayd\u0131nlatma ve y\u00f6nlendirme sisteminde bulunan b\u00fct\u00fcn ekipmanlar\u0131n (t\u00fcm dedekt\u00f6rler, t\u00fcm butonlar, \u2026) \u00f6rnekleme yap\u0131lmaks\u0131z\u0131n kontrol ve teste tabi tutulmas\u0131 ve sonu\u00e7lar\u0131n\u0131n raporda belirtilmesi gerekmektedir (Kriter 30).<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Kontrol kriterleri (ZPKK04)<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th>No<\/th><th>Kriter<\/th><th>Ne kontrol edilir<\/th><th>Dayanak<\/th><\/tr><\/thead><tbody><tr><td>&#8211;<\/td><td><strong>Haz\u0131rl\u0131k<\/strong><\/td><td>Kontrol yap\u0131lacak tesisin genel bilgileri (\u00f6l\u00e7\u00fcm tarihi, sistem detay bilgileri, bina ile ilgili bilgiler vb.) kontrol edildikten sonra tesise ait proje olup olmad\u0131\u011f\u0131 sorgulanmal\u0131d\u0131r. Tesiste kontrol panelinin \u00f6zellikleri ve \u00e7al\u0131\u015fma sistemi hakk\u0131nda bilgili ve deneyimli bir personel yok ise, bak\u0131m firmas\u0131ndan bir personelin testler esnas\u0131nda orada bulunmas\u0131 i\u015fverenden talep edilir. Periyodik kontrol Bak\u0131m Firmas\u0131 e\u015fli\u011finde yap\u0131lmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik, Elektrik \u0130\u00e7 Tesisler Y\u00f6netmeli\u011fi<\/td><\/tr><tr><td>1<\/td><td><strong>Yetkili ve e\u011fitimli personel var m\u0131?<\/strong><\/td><td>Tesiste yang\u0131n alg\u0131lama ve uyar\u0131 sistemlerini tan\u0131yan, herhangi bir alarm durumunda ne yapaca\u011f\u0131n\u0131 bilen yetkili ve e\u011fitimli ki\u015fi veya ki\u015filer bulunmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-129<\/td><\/tr><tr><td>2<\/td><td><strong>Yang\u0131n g\u00fcvenli\u011fi sorumlular\u0131 belirlenmi\u015f mi?<\/strong><\/td><td>Binan\u0131n her kat\u0131, b\u00f6l\u00fcm\u00fc veya tamam\u0131 i\u00e7in g\u00f6revliler aras\u0131ndan yang\u0131n g\u00fcvenli\u011fi sorumlular\u0131 se\u00e7ilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-125<\/td><\/tr><tr><td>3<\/td><td><strong>Yang\u0131n alarm panelinin durumu (ekran-tu\u015flar-LED\u2019ler)<\/strong><\/td><td>\u00d6ncelikle ilgili binada otomatik yang\u0131n alg\u0131lama ve uyar\u0131 sistemi zorunlulu\u011fu olup olmad\u0131\u011f\u0131n\u0131n tespiti yap\u0131lmal\u0131d\u0131r; bu tespit Y\u00f6netmelik Ek-7&#8217;deki tabloya g\u00f6re yap\u0131l\u0131r. Otomatik sistem gerekiyorsa yang\u0131n kontrol panelinin durumu, ekran\u0131, tu\u015flar\u0131 vb. g\u00f6zle kontrol edilir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-75, Ek-7<\/td><\/tr><tr><td>4<\/td><td><strong>Acil durum anons sistemi<\/strong><\/td><td>Acil durum anons sisteminin gereklili\u011fi Y\u00f6netmelik Md-81-(7)&#8217;ye g\u00f6re belirlenir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-81-(7)<\/td><\/tr><tr><td>5<\/td><td><strong>Bak\u0131m\/servis kay\u0131tlar\u0131 tutuluyor mu?<\/strong><\/td><td>Sistemin bak\u0131m\u0131, belirli periyotlarla d\u00fczenli olarak yap\u0131lmal\u0131 ve kay\u0131tlar\u0131 tutulmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-84<\/td><\/tr><tr><td>6<\/td><td><strong>Sistem k\u00fct\u00fc\u011f\u00fc belgesi var m\u0131?<\/strong><\/td><td>Bir sistem k\u00fct\u00fc\u011f\u00fcn\u00fcn tutulmas\u0131 ve sistemden kaynaklanan veya sistemi etkileyen b\u00fct\u00fcn olaylar\u0131n bu k\u00fct\u00fc\u011fe kaydedilmesi gerekir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>7<\/td><td><strong>Kontrol paneli ve varsa tekrarlay\u0131c\u0131 panellerin yerle\u015fim durumu<\/strong><\/td><td>Ana kontrol paneli ve varsa tekrarlay\u0131c\u0131 paneller rahatl\u0131kla g\u00f6r\u00fclebilecek yerlere yerle\u015ftirilmelidir.<\/td><td><\/td><\/tr><tr><td>8<\/td><td><strong>Kontrol paneli s\u00fcrekli izlenebilir durumda m\u0131?<\/strong><\/td><td>Yang\u0131n kontrol panelleri s\u00fcrekli izlenebilecek durumda olmal\u0131d\u0131r.<\/td><td><\/td><\/tr><tr><td>9<\/td><td><strong>Dedekt\u00f6r ve\/veya buton adreslemesi veya yerle\u015fim haritas\u0131 var m\u0131?<\/strong><\/td><td>Dedekt\u00f6r ve uyar\u0131 butonlar\u0131 adreslenerek bir plan \u00fczerinde g\u00f6sterilmelidir. Bu plan sistemin onayl\u0131 projesine uygun olmal\u0131d\u0131r; sonradan yap\u0131lan ilave veya tadilatlar bu plan \u00fczerinde i\u015faretlenmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>10<\/td><td><strong>Asma tavan, y\u00fckseltilmi\u015f d\u00f6\u015feme vb. i\u00e7inde kalan dedekt\u00f6rlerin uyar\u0131lar\u0131n\u0131n g\u00f6r\u00fclebilmesi i\u00e7in paralel ihbar lambalar\u0131 var m\u0131?<\/strong><\/td><td>G\u00f6r\u00fclemeyecek hacimler i\u00e7inde kalan dedekt\u00f6rler i\u00e7in rahatl\u0131kla g\u00f6r\u00fclebilecek yerlere paralel uyar\u0131 lambalar\u0131 tesis edilmi\u015f olmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>11<\/td><td><strong>\u00c7evrimlerde k\u0131sa devre ve a\u00e7\u0131k devre korumas\u0131<\/strong><\/td><td>Her \u00e7evrimde k\u0131sa devre ve a\u00e7\u0131k devre korumas\u0131 olmal\u0131d\u0131r ve bu hatal\u0131 olaylar yang\u0131n kontrol paneli \u00fczerindeki sinyal lambalar\u0131 ile uyar\u0131lmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>12<\/td><td><strong>Kullanma talimat\u0131 var m\u0131?<\/strong><\/td><td>Yang\u0131n kontrol paneli ve varsa tekrarlay\u0131c\u0131 kontrol panellerine ait, \u00fcretici firma taraf\u0131ndan sa\u011flanan bir kullanma talimat\u0131 olmal\u0131 ve bu talimat yang\u0131n g\u00fcvenli\u011fi ile ilgili personelin her an ula\u015fabilece\u011fi bir yerde muhafaza edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>13<\/td><td><strong>Ak\u00fc kapasitesi, gerilimi, ak\u0131m\u0131 ve fiziki durumu<\/strong><\/td><td>Ak\u00fc kapasitesi kontrol edilir; panel \u00fczerinde ak\u00fc gerilimi ile ilgili test butonu varsa ak\u00fc gerilimi test butonu ile kontrol edilir, ya da multimetre ile \u00f6l\u00e7\u00fcm yap\u0131l\u0131r. Ak\u00fcn\u00fcn fiziki durumu da kontrol edilir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>14<\/td><td><strong>Dedekt\u00f6rlerin \u00e7al\u0131\u015fma ortam\u0131na uyumu ve yeterli olmas\u0131<\/strong><\/td><td>Sistemde kullan\u0131lan dedekt\u00f6rlerin onayl\u0131 projesine g\u00f6re, uygun ortamlarda kullan\u0131ld\u0131\u011f\u0131 kontrol edilir. Proje harici ilaveler ve tadilatlar yap\u0131lm\u0131\u015fsa buralarda kullan\u0131lan dedekt\u00f6rlerin ortama uygunlu\u011fu kontrol edilir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>15<\/td><td><strong>Sesli-siren\/\u0131\u015f\u0131kl\u0131-fla\u015f\u00f6r uyar\u0131lar\u0131n\u0131n yerle\u015fim durumu ve yeterli olmas\u0131<\/strong><\/td><td>Sesli-siren\/\u0131\u015f\u0131kl\u0131-fla\u015f\u00f6r uyar\u0131lar\u0131n\u0131n yerle\u015fim durumu ve yeterlili\u011fi onayl\u0131 projesine g\u00f6re kontrol edilir; ilave tadilatlar yap\u0131lm\u0131\u015fsa bunlar\u0131n da yerle\u015fim durumu ve yeterlili\u011fi kontrol edilir. Ses seviyesi \u00f6l\u00e7\u00fcm\u00fc yap\u0131l\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik<\/td><\/tr><tr><td>16<\/td><td><strong>Yang\u0131n alarm ve uyar\u0131 kablolar\u0131n\u0131n uygunlu\u011fu<\/strong><\/td><td>Yang\u0131n alg\u0131lama ve uyar\u0131 sistemlerinde kullan\u0131lan kablolar TSE Standartlar\u0131na uygun, halojenden ar\u0131nd\u0131r\u0131lm\u0131\u015f ve yang\u0131na en az 60 dakika dayanabilecek tipte olmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-83-(1),(2),(3),(4),(5)<\/td><\/tr><tr><td>17<\/td><td><strong>Acil durum ayd\u0131nlatma sistemi varl\u0131\u011f\u0131, yeterlili\u011fi-di\u011fer gerekli alanlar<\/strong><\/td><td>B\u00fct\u00fcn ka\u00e7\u0131\u015f yollar\u0131nda, asans\u00f6r hollerinde, toplanma ama\u00e7l\u0131 alanlarda, y\u00fcr\u00fcyen merdivenlerde, y\u00fcksek riskli hareketli makineler ve kimyevi madde bulunan yerlerde, elektrik da\u011f\u0131t\u0131m ve jenerat\u00f6r odalar\u0131nda, pompa istasyonlar\u0131nda, kapal\u0131 otoparklarda, ilk yard\u0131m ve emniyet ekipman\u0131n\u0131n bulundu\u011fu yerlerde, normal ayd\u0131nlatman\u0131n kesilmesi halinde en az 60 dakika yanacak acil ayd\u0131nlatma tertibat\u0131 bulunmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-71, Md-72-(1),(2),(3),(4),(5),(6),(7),(8), TS EN 12464-1<\/td><\/tr><tr><td>18<\/td><td><strong>Ka\u00e7\u0131\u015f yollar\u0131nda acil durum y\u00f6nlendirme i\u015faretleri varl\u0131\u011f\u0131, yeterlili\u011fi<\/strong><\/td><td>Birden fazla \u00e7\u0131k\u0131\u015f\u0131 olan b\u00fct\u00fcn binalarda acil durum y\u00f6nlendirmesi yap\u0131lmal\u0131d\u0131r. Acil durum y\u00f6nlendirme i\u015faretleri de normal ayd\u0131nlatman\u0131n kesilmesi durumunda en az 60 dakika yanabilecek \u00f6zellikte olmal\u0131d\u0131r; kullanma alanlar\u0131na g\u00f6re renkleri ve y\u00fckseklikleri Y\u00f6netmelikte belirtilmi\u015ftir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-73-(1),(2),(3),(4),(5),(6),(7)<\/td><\/tr><tr><td>19<\/td><td><strong>Duman damperleri a\u00e7\u0131k\/kapal\u0131 konum bilgilerinin do\u011frudan \u00e7evrimlere ba\u011fl\u0131 kontak izleme cihazlar ile izlenebilirli\u011fi<\/strong><\/td><td>Duman kontrol sistemlerine ait a\u00e7\u0131k\/kapal\u0131 konum bilgileri kolayca izlenebilir durumda bulunmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-85,86,87,88<\/td><\/tr><tr><td>20<\/td><td><strong>\u0130klimlendirme\/havaland\u0131rma sistemi ve duman egzost sistemi sinyal kontrol\u00fc<\/strong><\/td><td>\u0130klimlendirme, havaland\u0131rma ve duman egzoz sistemi sinyalleri kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-87,88<\/td><\/tr><tr><td>21<\/td><td><strong>Yang\u0131n alarm sisteminin di\u011fer otomatik s\u00f6nd\u00fcrme sistemleri ile entegre olma durumu<\/strong><\/td><td>Yang\u0131n alarm sistemi, bir yang\u0131n an\u0131nda (binada otomatik s\u00f6nd\u00fcrme sistemi varsa) otomatik s\u00f6nd\u00fcrme sistemini harekete ge\u00e7irecek sinyali vermelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-90<\/td><\/tr><tr><td>22<\/td><td><strong>Yang\u0131n s\u00f6nd\u00fcrme sistemi ak\u0131\u015f anahtarlar\u0131, hat kesme vanalar\u0131, yang\u0131n pompalar\u0131 \u00e7al\u0131\u015fma fonksiyonlar\u0131 konum bilgisi izlenebilirli\u011fi<\/strong><\/td><td>Yang\u0131n alarm sistemi, bir yang\u0131n an\u0131nda (binada otomatik s\u00f6nd\u00fcrme sistemi varsa) otomatik s\u00f6nd\u00fcrme sistemini harekete ge\u00e7irecek sinyali vermelidir. Konum bilgileri panel \u00fczerinde izlenebilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-90<\/td><\/tr><tr><td>23<\/td><td><strong>Yang\u0131n alg\u0131lama ve uyar\u0131 sisteminin bina otomasyon sistemi ile ba\u011flant\u0131 ve haberle\u015fme kontrol\u00fc<\/strong><\/td><td>Yang\u0131n alarm sistemi, bir yang\u0131n an\u0131nda bina otomasyon sistemi ile haberle\u015febilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-82<\/td><\/tr><tr><td>24<\/td><td><strong>Asans\u00f6rlerin yang\u0131n an\u0131nda davran\u0131\u015flar\u0131 kontrol\u00fc<\/strong><\/td><td>Y\u00fcksek binalarda ve topluma a\u00e7\u0131k yap\u0131larda kullan\u0131lan asans\u00f6rler, bir yang\u0131n uyar\u0131s\u0131 al\u0131nd\u0131\u011f\u0131nda, kap\u0131lar\u0131n\u0131 a\u00e7madan, do\u011frultular\u0131 ne olursa olsun acil \u00e7\u0131k\u0131\u015f kat\u0131na d\u00f6necek ve kap\u0131lar\u0131 a\u00e7\u0131k bekleyecek \u00f6zellikte olmal\u0131d\u0131r. Bunun sa\u011fland\u0131\u011f\u0131 yang\u0131n paneli \u00fczerinden kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-62,63<\/td><\/tr><tr><td>25<\/td><td><strong>Yang\u0131n an\u0131nda asans\u00f6r kuyular\u0131 ve yang\u0131n merdiveni kovalar\u0131 bas\u0131n\u00e7land\u0131rma sistemi kontrolleri<\/strong><\/td><td>Konutlar hari\u00e7 merdiven kovas\u0131n\u0131n 30,5 m&#8217;den fazla oldu\u011fu merdiven kovalar\u0131nda ve acil durum asans\u00f6rlerinin bulundu\u011fu asans\u00f6r kuyular\u0131nda bas\u0131n\u00e7land\u0131rma sistemi zorunludur. Bir yang\u0131n uyar\u0131 an\u0131nda bu durumun sa\u011fland\u0131\u011f\u0131 kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-89<\/td><\/tr><tr><td>26<\/td><td><strong>Ge\u00e7i\u015f kontrol sistemleri uygunlu\u011fu (d\u00f6ner kap\u0131, turnike, acil \u00e7\u0131k\u0131\u015f kap\u0131lar\u0131)<\/strong><\/td><td>Ge\u00e7i\u015f kontrol sistemleri, bir yang\u0131n uyar\u0131 an\u0131nda a\u00e7\u0131labilecek \u015fekilde d\u00fczenlenmelidir. Yang\u0131n paneli \u00fczerinden bu durumun sa\u011fland\u0131\u011f\u0131 kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-82<\/td><\/tr><tr><td>27<\/td><td><strong>Yang\u0131n b\u00f6lme kap\u0131lar\u0131 elektromanyetik tutucular\u0131 kontrol\u00fc<\/strong><\/td><td>Yang\u0131n b\u00f6lme kap\u0131lar\u0131, bir yang\u0131n uyar\u0131 an\u0131nda a\u00e7\u0131labilecek \u015fekilde d\u00fczenlenmelidir. Yang\u0131n paneli \u00fczerinden bu durumun sa\u011fland\u0131\u011f\u0131 kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-82<\/td><\/tr><tr><td>28<\/td><td><strong>Yang\u0131n an\u0131nda patlay\u0131c\u0131 gaz da\u011f\u0131t\u0131m sistemlerinin kontrol\u00fc<\/strong><\/td><td>Yang\u0131n an\u0131nda patlay\u0131c\u0131 gaz da\u011f\u0131t\u0131m sistemlerine ait gaz giri\u015f vanalar\u0131 kapat\u0131lacak \u015fekilde d\u00fczenlenmelidir. Yang\u0131n paneli \u00fczerinden bu durumun sa\u011fland\u0131\u011f\u0131 kontrol edilmelidir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-82<\/td><\/tr><tr><td>29<\/td><td><strong>G\u00fcvenlik devre ayr\u0131lmas\u0131<\/strong><\/td><td>CCTV, yang\u0131n uyar\u0131 ve alg\u0131lama vb. sistem kablolar\u0131 Bant I (zay\u0131f ak\u0131m) ve Bant II (kuvvetli ak\u0131m) kablolar\u0131ndan ayr\u0131 kablo yollar\u0131ndan \u00e7ekilmeli ya da aralar\u0131nda separat\u00f6r olmal\u0131d\u0131r.<\/td><td>TS CEN\/TS 54-14:2018, TS HD 60364-5-52 Binalarda elektrik tesisat\u0131-B\u00f6l\u00fcm 5-52, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-83-(4)<\/td><\/tr><tr><td>30<\/td><td><strong>Testler<\/strong><\/td><td>B\u00f6l\u00fcm ad\u0131 ve tan\u0131m\u0131 yap\u0131larak, hangi \u00e7evrimde hangi ekipmandan ka\u00e7 adet varsa bunlar\u0131n hepsinin testleri yap\u0131l\u0131r ve projesindeki kodu veya tan\u0131m\u0131 belirtilerek rapor format\u0131ndaki tabloya i\u015flenir; yang\u0131n alg\u0131lama, uyar\u0131, acil ayd\u0131nlatma ve y\u00f6nlendirme sistemindeki b\u00fct\u00fcn ekipmanlar\u0131n (t\u00fcm dedekt\u00f6rler, t\u00fcm butonlar, \u2026) \u00f6rnekleme yap\u0131lmaks\u0131z\u0131n kontrol ve teste tabi tutulmas\u0131 ve sonu\u00e7lar\u0131n\u0131n raporda belirtilmesi gerekmektedir. Duman dedekt\u00f6rlerinin testleri mutlaka duman spreyleri ile yap\u0131lmal\u0131d\u0131r; \u0131s\u0131 dedekt\u00f6rlerinin testleri f\u00f6n cihazlar\u0131 ile yap\u0131labilir; bu testler yap\u0131l\u0131rken uyar\u0131 amac\u0131yla kullan\u0131lan siren veya fla\u015f\u00f6rlerin hepsinin aktif oldu\u011fu da do\u011frulanmal\u0131d\u0131r; kar\u015f\u0131l\u0131kl\u0131 olarak kullan\u0131lan lineer duman dedekt\u00f6rlerinin testleri aralar\u0131na \u015feffaf olmayan bir engel tutularak yap\u0131lmal\u0131d\u0131r; b\u00fct\u00fcn bu testler yap\u0131l\u0131rken ilgili kontrol paneli \u00fczerinde adreslemelerin do\u011fru yap\u0131l\u0131p yap\u0131lmad\u0131\u011f\u0131na da bak\u0131lmal\u0131d\u0131r. Normal ko\u015fullarda kullan\u0131lan elektrik tesisat\u0131n\u0131n yang\u0131n an\u0131nda ek riske neden olmayacak \u015fekilde tesis edilip edilmedi\u011fi (yang\u0131n an\u0131nda elektrik tesisat\u0131nda kesicilerin \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131, enerjisi kesilmemesi gereken b\u00f6l\u00fcmlerin yedek enerji kaynaklar\u0131n\u0131n bulunup bulunmad\u0131\u011f\u0131 ve devreye otomatik girip girmedi\u011fi) hususu de\u011ferlendirilecektir.<\/td><td>TS CEN\/TS 54-14:2018, Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik Md-84<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Dok\u00fcmandaki s\u0131n\u0131r de\u011ferler ve e\u015fikler<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Kriter 16: Yang\u0131n alg\u0131lama ve uyar\u0131 sistemlerinde kullan\u0131lan kablolar yang\u0131na en az 60 dakika dayanabilecek tipte olmal\u0131d\u0131r.<\/li><li>Kriter 17: Belirtilen alanlarda normal ayd\u0131nlatman\u0131n kesilmesi halinde en az 60 dakika yanacak acil ayd\u0131nlatma tertibat\u0131 bulunmal\u0131d\u0131r.<\/li><li>Kriter 18: Acil durum y\u00f6nlendirme i\u015faretleri normal ayd\u0131nlatman\u0131n kesilmesi durumunda en az 60 dakika yanabilecek \u00f6zellikte olmal\u0131d\u0131r.<\/li><li>Kriter 25: Konutlar hari\u00e7 merdiven kovas\u0131n\u0131n 30,5 m&#8217;den fazla oldu\u011fu merdiven kovalar\u0131nda (ve acil durum asans\u00f6rlerinin bulundu\u011fu asans\u00f6r kuyular\u0131nda) bas\u0131n\u00e7land\u0131rma sistemi zorunludur.<\/li><li>ZPKR04 Sonu\u00e7 ve Kanaat: sistemin mevcut \u015fartlar alt\u0131nda kullan\u0131m\u0131 1 y\u0131l s\u00fcreyle UYGUNDUR \/ UYGUN DE\u011e\u0130LD\u0130R olarak beyan edilir.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Rapor format\u0131n\u0131n b\u00f6l\u00fcmleri (ZPKR04)<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>1. F\u0130RMA B\u0130LG\u0130LER\u0130<\/li><li>2. TES\u0130S B\u0130LG\u0130LER\u0130 (2.1. S\u0130STEM DETAY B\u0130LG\u0130LER\u0130; 2.2. B\u0130NA \u0130LE \u0130LG\u0130L\u0130 TESP\u0130T ED\u0130LEN B\u0130LG\u0130LER)<\/li><li>3. TEST DE\u011eERLER\u0130<\/li><li>4. \u00d6L\u00c7\u00dcM ALETLER\u0130 B\u0130LG\u0130LER\u0130<\/li><li>5. TESP\u0130T VE DE\u011eERLEND\u0130RMELER (5.1. G\u00d6ZLE MUAYENELER VE BELGE KONTROLLER\u0130; 5.2. YANGIN ALGILAMA VE UYARI C\u0130HAZLARI KONTROL\u00dc VE TESTLER (\u00d6rnekleme yap\u0131lmadan t\u00fcm ekipmanlar))<\/li><li>6. KUSUR A\u00c7IKLAMALARI<\/li><li>FOTO\u011eRAFLAR (numaras\u0131z b\u00f6l\u00fcm)<\/li><li>7. NOTLAR<\/li><li>8. SONU\u00c7 VE KANAAT<\/li><li>9. PER\u0130YOD\u0130K KONTROLLER\u0130 YAPMAYA YETK\u0130L\u0130 K\u0130\u015e\u0130 B\u0130LG\u0130LER\u0130 ve ONAY<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Raporda doldurulmas\u0131 istenen ba\u015fl\u0131ca bilgiler:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00dcst bilgi: Dok\u00fcman Kodu ZPKR04, Yay\u0131m Tarihi 18.07.2025, Revizyon No -, Revizyon Tarihi -, Y\u00fcr\u00fcrl\u00fck Tarihi 01.09.2025.<\/li><li>1. Firma Bilgileri: Firma Ad\u0131, Periyodik Kontrol Adresi, SGK Sicil Numaras\u0131, Rapor Numaras\u0131, Rapor Tarihi, \u0130SG-KAT\u0130P S\u00f6zle\u015fme ID, Periyodik Kontrol Ba\u015flang\u0131\u00e7 Tarihi ve Saati, Periyodik Kontrol Biti\u015f Tarihi ve Saati, Bir Sonraki Periyodik Kontrol Tarihi.<\/li><li>Periyodik Kontrol Metodu ve Kapsam\u0131 (formda bas\u0131l\u0131): TSE CEN\/TS 54-14: Yang\u0131n Alg\u0131lama ve Yang\u0131n Alarm Sistemleri &#8211; B\u00f6l\u00fcm 14: Planlama, Tasar\u0131m, Kurulum, Devreye Alma, Kullan\u0131m ve Bak\u0131m \u0130\u00e7in Rehber; \u0130\u015f Ekipmanlar\u0131n\u0131n Kullan\u0131m\u0131nda Sa\u011fl\u0131k ve G\u00fcvenlik \u015eartlar\u0131 Y\u00f6netmeli\u011fi; Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik; Elektrik \u0130\u00e7 Tesisleri Y\u00f6netmeli\u011fi.<\/li><li>2.1. Sistem Detay Bilgileri: Yang\u0131n alg\u0131lama sistemi (Otomatik\/Manuel); Yang\u0131n uyar\u0131 sistemi (I\u015f\u0131kl\u0131\/Sesli\/I\u015f\u0131k+Ses\/Anons\/Di\u011fer); Sistem \u00e7al\u0131\u015fma tipi (Adresli\/Konvansiyonel); Kontrol nedeni (Periyodik Kontrol\/\u0130lk Kontrol); Proje onay kurumu; Proje onay tarih ve say\u0131s\u0131; Kontrol paneli marka\/model; Kontrol paneli seri no.\/imal y\u0131l\u0131; Kontrol paneli \u00e7al\u0131\u015fma gerilimi; Kontrol paneli yeri; \u0130lk kontrol\/devreye alma tarihi; Son kontrol tarihi; Alg\u0131lama ekipmanlar\u0131 (Duman (optik) dedekt\u00f6r\u00fc\/Is\u0131 dedekt\u00f6r\u00fc\/\u0130hbar butonu); Uyar\u0131 ekipmanlar\u0131 (Siren\/Fla\u015f\u00f6r); S\u00f6nd\u00fcrme ekipmanlar\u0131 (Otomatik s\u00f6nd\u00fcrme\/KKT \u00d6zellikli yang\u0131n t\u00fcpleri\/CO\u2070 \u00d6zellikli yang\u0131n t\u00fcpleri\/Hidrantlar-Yang\u0131n dolaplar\u0131).<\/li><li>2.2. Bina ile \u0130lgili Tespit Edilen Bilgiler: Tesisatta kapsaml\u0131 de\u011fi\u015fiklik var m\u0131? (Var\/Yok\/Belirlenemedi); Bir \u00f6nceki periyodik kontrol etiketi var m\u0131? (Var\/Yok); Bina kullanma s\u0131n\u0131f\u0131 (Konut, Toplanma ama\u00e7l\u0131 bina, Depolama ama\u00e7l\u0131 tesis, Y\u00fcksek tehlikeli bina, Kar\u0131\u015f\u0131k kullan\u0131m ama\u00e7l\u0131 bina, End\u00fcstriyel yap\u0131, Konaklama ama\u00e7l\u0131 bina, Kurumsal bina, B\u00fcro binas\u0131, Ticari); Bina tehlike s\u0131n\u0131f\u0131 (D\u00fc\u015f\u00fck\/Orta\/Y\u00fcksek tehlike); Tehlike kategorisi (1\/2\/3\/4); Bina toplam kullan\u0131m alan\u0131 (m\u00b2); Kat say\u0131s\u0131; Bina y\u00fcksekli\u011fi\/Yap\u0131 y\u00fcksekli\u011fi (m); Yap\u0131 kullanma izin tarihi; B\u00f6l\u00fcm say\u0131s\u0131; Varsa di\u011fer tespitler.<\/li><li>3. Test De\u011ferleri: ba\u015fl\u0131k alt\u0131nda bo\u015f bir alan bulunur; alt alan tan\u0131mlanmam\u0131\u015ft\u0131r.<\/li><li>4. \u00d6l\u00e7\u00fcm Aletleri Bilgileri (iki cihaz i\u00e7in yan yana): Cihaz ad\u0131, Kalibrasyon tarihi, Kalibrasyon ge\u00e7erlilik tarihi, Seri numaras\u0131, Kalibrasyon numaras\u0131.<\/li><li>5.1. G\u00f6zle Muayeneler ve Belge Kontrolleri: &#8216;Kontrol Kriteri \u2013 De\u011ferlendirme&#8217; iki s\u00fctun \u00e7ifti; gruplar: \u00d6N KONTROLLER; YANGIN ALGILAMA VE YANGIN UYARI S\u0130STEM\u0130 VE TES\u0130SATI; AC\u0130L DURUM AYDINLATMA VE AC\u0130L DURUM Y\u00d6NLEND\u0130RME S\u0130STEM\u0130; YANGIN ANINDA D\u0130\u011eER MEKAN\u0130K, ELEKTR\u0130K VE ELEKTRON\u0130K S\u0130STEMLERLE ENTEGRASYON.<\/li><li>5.1 Acil durum ayd\u0131nlatma grubunda kriter listesinde ayr\u0131ca numaralanmam\u0131\u015f kalemler de yer al\u0131r: Acil durum ayd\u0131nlatma armat\u00fcrleri uygunlu\u011fu; Acil durum ayd\u0131nlatma sistemi varl\u0131\u011f\u0131, yeterlili\u011fi-panel \u00f6n\u00fc (lux de\u011feri TS EN 12464\u2019e g\u00f6re); Acil \u00e7\u0131k\u0131\u015f hollerinde acil durum y\u00f6nlendirme i\u015faretleri varl\u0131\u011f\u0131, yeterlili\u011fi; Acil durum ayd\u0131nlatma \u00fcnitelerinin ayd\u0131nlatma s\u00fcrelerinin uygunlu\u011fu; Acil durum ayd\u0131nlatma \u00fcnitelerinin ayd\u0131nlatma seviyelerinin uygunlu\u011fu; Acil durum ayd\u0131nlatmas\u0131 ve y\u00f6nlendirmesi elektrik kesildi\u011finde otomatik devreye girmesi.<\/li><li>5.1 Entegrasyon grubunda ayr\u0131 kalem: Yang\u0131n an\u0131nda elektrik tesisat\u0131nda kesicilerin \u00e7al\u0131\u015f\u0131p \u00e7al\u0131\u015fmad\u0131\u011f\u0131, enerjisi kesilmemesi gereken b\u00f6l\u00fcmlerin yedek enerji kaynaklar\u0131n\u0131n bulunup bulunmad\u0131\u011f\u0131 ve devreye otomatik girip girmedi\u011fi.<\/li><li>5.2. Yang\u0131n Alg\u0131lama ve Uyar\u0131 Cihazlar\u0131 Kontrol\u00fc ve Testler (\u00f6rnekleme yap\u0131lmadan t\u00fcm ekipmanlar) tablosu: Tan\u0131m\/Kod, B\u00f6l\u00fcm Ad\u0131\/Tan\u0131m\u0131, Ekipman ad\u0131\/Adedi; De\u011ferlendirme s\u00fctunlar\u0131: Projede g\u00f6sterilen yerde mi?, Eri\u015fim durumu, Montaj durumu, Test, Sesli uyar\u0131 yeterli mi?, I\u015f\u0131kl\u0131 uyar\u0131 yeterli mi?, Adresleme do\u011fru mu?<\/li><li>5.2 tablo sat\u0131rlar\u0131 loop (\u00e7evrim) baz\u0131ndad\u0131r (Loop 1, Loop 2 \u2026); ekipman sat\u0131rlar\u0131: Optik duman dedekt\u00f6r\u00fc, Is\u0131 dedekt\u00f6r\u00fc, Yang\u0131n Alarm butonu, Siren, Fla\u015f\u00f6r (\u0131\u015f\u0131kl\u0131 ve sesli), Di\u011fer. \u00d6rnek Loop 1 de\u011ferlendirmesi: dedekt\u00f6r ve butonlarda sesli\/\u0131\u015f\u0131kl\u0131 uyar\u0131 UG, siren i\u00e7in \u0131\u015f\u0131kl\u0131 uyar\u0131 UG, di\u011ferleri U.<\/li><li>Kriter 30 gere\u011fi her ekipman\u0131n projesindeki kodu veya tan\u0131m\u0131 belirtilerek rapor format\u0131ndaki tabloya i\u015flenir.<\/li><li>De\u011ferlendirme i\u015faretleri: UYGUN (U), UYGUN DE\u011e\u0130L (UD), UYGULANMAZ (UG); kusur derecesi (*) hafif, (**) a\u011f\u0131r.<\/li><li>6. Kusur A\u00e7\u0131klamalar\u0131 ve Foto\u011fraflar: serbest metin \/ foto\u011fraf alan\u0131.<\/li><li>7. Notlar: serbest metin alan\u0131 (test yap\u0131lamam\u0131\u015fsa burada belirtilir \u2014 A\u00e7\u0131klama 1).<\/li><li>8. Sonu\u00e7 ve Kanaat: \u2018Periyodik kontrol tarihi itibariyle yukar\u0131da teknik \u00f6zellikleri belirtilen Yang\u0131n Alg\u0131lama ve Uyar\u0131 Sisteminin periyodik muayenesi sonras\u0131nda mevcut \u015fartlar alt\u0131nda kullan\u0131m\u0131 1 y\u0131l s\u00fcreyle; UYGUNDUR \/ UYGUN DE\u011e\u0130LD\u0130R.\u2019 se\u00e7imi; hafif kusur notu ve a\u011f\u0131r kusur tan\u0131m\u0131 ile A\u00e7\u0131klamalar 1\u20135 formda bas\u0131l\u0131d\u0131r.<\/li><li>9. Periyodik Kontrolleri Yapmaya Yetkili Ki\u015fi Bilgileri ve Onay: Ad\u0131 Soyad\u0131, Mesle\u011fi, Yetkili Ki\u015fi Kay\u0131t Numaras\u0131, \u0130mzas\u0131.<\/li><li>Rapor sonu: \u2018Bu rapor &#8230;&#8230;&#8230;&#8230; [yaz\u0131 (rakam)] n\u00fcsha olarak haz\u0131rlanm\u0131\u015ft\u0131r.\u2019<\/li><li>ZPKK04 &#8216;Notlar&#8217; sat\u0131r\u0131na g\u00f6re projeyi onaylayanlar\u0131n adlar\u0131 soyadlar\u0131, imzalar\u0131, meslek unvanlar\u0131, diploma numaralar\u0131, tarih ve say\u0131, proje onay ge\u00e7erlilik s\u00fcresi vb. eklenecektir (rapor format\u0131nda bunun i\u00e7in ayr\u0131 alan yok; 2.1&#8217;de yaln\u0131z &#8216;Proje onay kurumu&#8217; ve &#8216;Proje onay tarih ve say\u0131s\u0131&#8217; alanlar\u0131 var).<\/li><li>Rapor format\u0131nda EK\u0130PNET numaras\u0131 alan\u0131 yer almamaktad\u0131r; s\u00f6zle\u015fme kimli\u011fi olarak &#8216;\u0130SG-KAT\u0130P S\u00f6zle\u015fme ID&#8217; alan\u0131 bulunur.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Kusur derecelendirmesi ve dok\u00fcmandaki notlar<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>ZPKK04 Not 1: Kusur derecesi: (*) hafif kusurlu ve (**) a\u011f\u0131r kusurlu anlam\u0131nda kullan\u0131lmaktad\u0131r.<\/li><li>ZPKK04 Not 2: Bir i\u015f ekipman\u0131n\u0131n imalat mevzuat\u0131 veya standard\u0131, yukar\u0131daki kontrol kriterlerinin uygulanmas\u0131na izin vermiyorsa, sadece ilgili ekipmanda bu kriter uygulanmaz. Bu durum ilgili imalat mevzuat\u0131 veya standart numaras\u0131na at\u0131f yap\u0131larak ifade edilir.<\/li><li>ZPKK04 Not 3: Onay Kurumu taraf\u0131ndan onayl\u0131 proje yoksa sadece durum tespiti yap\u0131labilir. Yap\u0131lan tespitlerin uygunlu\u011fu proje ihtiyac\u0131n\u0131 ortadan kald\u0131rmaz.<\/li><li>ZPKK04 Not 4: Periyodik kontrol, yang\u0131n alg\u0131lama ve uyar\u0131 sistemi projesinin do\u011frulu\u011funu kapsamaz. Onayl\u0131 projeyi temel al\u0131r.<\/li><li>ZPKK04 tablo &#8216;Notlar&#8217; sat\u0131r\u0131: Projeyi onaylayanlar\u0131n adlar\u0131 soyadlar\u0131, imzalar\u0131, meslek unvanlar\u0131, diploma numaralar\u0131, tarih ve say\u0131, proje onay ge\u00e7erlilik s\u00fcresi vb. eklenecektir.<\/li><li>ZPKK04 tablo &#8216;Notlar&#8217; sat\u0131r\u0131: Tesisat\u0131n Projeye Uygunlu\u011fu ve Projenin Binalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmeli\u011fe ve ilgili standartlara uygunlu\u011fu de\u011ferlendirilecektir.<\/li><li>ZPKR04 (6. Kusur A\u00e7\u0131klamalar\u0131 alt\u0131): Kusur derecesi; (*) hafif kusurlu ve (**) a\u011f\u0131r kusurlu anlam\u0131nda kullan\u0131lmaktad\u0131r. De\u011ferlendirme \u201cUYGUN (U)\u201d, \u201cUYGUN DE\u011e\u0130L (UD)\u201d ve \u201cUYGULANMAZ (UG)\u201d olarak yap\u0131l\u0131r.<\/li><li>ZPKR04 (8. Sonu\u00e7 ve Kanaat): Tespit edilen hafif kusurlar\u0131n bir sonraki periyodik kontrol tarihine kadar giderilmesi gereklidir. (Bu not, sadece hafif kusur tespit edilmesi durumunda yaz\u0131lacakt\u0131r.)<\/li><li>ZPKR04 A\u011f\u0131r kusurlar tan\u0131m\u0131: a) Dedekt\u00f6rler, yang\u0131n uyar\u0131 butonlar\u0131 ve sirenlerin test sonu\u00e7lar\u0131 yetersiz ise, b) Yang\u0131n paneli gelen uyar\u0131lar\u0131 alg\u0131lam\u0131yorsa, c) Ka\u00e7\u0131\u015f yollar\u0131 ve \u00e7\u0131k\u0131\u015f hollerinde acil ayd\u0131nlatma d\u00fczenleri ve ayd\u0131nl\u0131k seviyesi yetersiz ise, d) Ak\u00fc gerilimi d\u00fc\u015f\u00fckse, a\u011f\u0131r kusur olarak de\u011ferlendirilmelidir.<\/li><li>ZPKR04 A\u00e7\u0131klama 1: Kontrol talep eden firmadan, kontrole gitmeden \u00f6nce \u201cDuman Dedekt\u00f6r\u00fc Test Aparat\u0131\u201d sa\u011flamas\u0131 istenir. B\u00f6yle bir aparat i\u015fyerinde mevcutsa duman dedekt\u00f6rlerinin testleri yap\u0131l\u0131r. Aksi takdirde, tehlikeli olaca\u011f\u0131ndan k\u00e2\u011f\u0131t veya bez yakarak test yap\u0131lmaz. Bu nedenle veya herhangi bir ba\u015fka nedenle test yap\u0131lamam\u0131\u015fsa notlar b\u00f6l\u00fcm\u00fcnde belirtilir.<\/li><li>ZPKR04 A\u00e7\u0131klama 2: Is\u0131 dedekt\u00f6rlerinin kontrol\u00fc \u201cIs\u0131 Dedekt\u00f6r\u00fc Test Aparat\u0131\u201d ile yap\u0131l\u0131r. \u0130\u015fyerinde b\u00f6yle bir aparat yok ise bu testler f\u00f6n cihazlar\u0131 ile yap\u0131labilir.<\/li><li>ZPKR04 A\u00e7\u0131klama 3: Yang\u0131n uyar\u0131 butonlar\u0131n\u0131n testleri kendi \u00fczerinden yap\u0131l\u0131r.<\/li><li>ZPKR04 A\u00e7\u0131klama 4: Siren testleri \u201cBinalar\u0131n Yang\u0131ndan Korunmas\u0131 Hakk\u0131nda Y\u00f6netmelik\u201d Md.81-(5) h\u00fck\u00fcmleri g\u00f6zetilerek yap\u0131lmal\u0131d\u0131r.<\/li><li>ZPKR04 A\u00e7\u0131klama 5: Periyodik kontrol, yang\u0131n alg\u0131lama ve uyar\u0131 sistemi projesinin do\u011frulu\u011funu kapsamaz. Onayl\u0131 projeyi temel al\u0131r. Proje bulunmamas\u0131 durumunda yap\u0131lan kontrol durum tespitine y\u00f6neliktir. Yap\u0131lan tespitlerin uygunlu\u011fu proje ihtiyac\u0131n\u0131 ortadan kald\u0131rmaz.<\/li><li>ZPKR04 (5.2 tablo alt\u0131): Loop 1 ile ilgili tablonun de\u011ferlendirme b\u00f6l\u00fcm\u00fc \u00f6rnek olarak doldurulmu\u015ftur.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">AES Innovation&#8217;\u0131n kapsam\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bu kontrol AES Innovation&#8217;\u0131n akreditasyon kapsam\u0131 d\u0131\u015f\u0131ndad\u0131r (akreditasyon alan\u0131m\u0131z elektrik tesisat\u0131 periyodik kontrol\u00fcd\u00fcr); kontrol, EK\u0130PNET&#8217;e kay\u0131tl\u0131 yetkili m\u00fchendislerimizce yap\u0131l\u0131r. Bakanl\u0131k format\u0131n\u0131n kullan\u0131lmas\u0131, kontrol\u00fc kimin yapt\u0131\u011f\u0131ndan ba\u011f\u0131ms\u0131z olarak zorunludur.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kontrol\u00fcn yap\u0131labilmesi i\u00e7in i\u015fveren ile kontrol\u00fc yapacak yetkili ki\u015fi aras\u0131nda, kontrolden en ge\u00e7 1 g\u00fcn \u00f6nce \u0130SG-KAT\u0130P \u00fczerinden s\u00f6zle\u015fme d\u00fczenlenip onaylanm\u0131\u015f olmal\u0131d\u0131r; s\u00f6zle\u015fmesiz d\u00fczenlenen rapor ge\u00e7ersizdir.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/aesinn.com\/iletisim\/\">Periyodik Kontrol Teklifi Al\u0131n<\/a><\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u0130lgili: <a href=\"https:\/\/aesinn.com\/yangin-tesisatlari-muayeneleri\/\">Hizmet sayfas\u0131<\/a> \u00b7 <a href=\"https:\/\/aesinn.com\/periyodik-kontrol-isg-katip-sozlesmesi-ekipnet-zorunlu-rapor-formatlari\/\">\u0130SG-KAT\u0130P s\u00f6zle\u015fmesi ve zorunlu rapor formatlar\u0131<\/a> \u00b7 <a href=\"https:\/\/aesinn.com\/is-ekipmanlari-yonetmeligi\/\">\u0130\u015f Ekipmanlar\u0131 Y\u00f6netmeli\u011fi ve Ek-III<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kaynaklar<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li><a href=\"https:\/\/isekipmanlari.csgb.gov.tr\/dokumanlar.aspx\">\u00c7SGB \u0130\u015f Ekipmanlar\u0131 dok\u00fcmanlar\u0131: ZPKK04 ve ZPKR04 (Zorunlu Dok\u00fcmanlar)<\/a><\/li><li><a href=\"https:\/\/isekipmanlari.csgb.gov.tr\/detay.aspx?d=1043\">\u00c7SGB: Elektrik grubu i\u015f ekipmanlar\u0131 zorunlu periyodik kontrol rapor format\u0131 ve kriterleri<\/a><\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">S\u0131k Sorulan Sorular<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">ZPKR04 format\u0131 ne zamandan beri zorunlu?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bakanl\u0131k duyurusuna g\u00f6re 01.09.2025 tarihinden itibaren yang\u0131n alg\u0131lama ve uyar\u0131 sistemleri periyodik kontrollerinde bu format\u0131n \u015feklen ve i\u00e7erik olarak eksiksiz kullan\u0131lmas\u0131 zorunludur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Format\u0131n g\u00f6r\u00fcn\u00fcm\u00fc de\u011fi\u015ftirilebilir mi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Ana ba\u015fl\u0131klar ve s\u0131ralar\u0131 de\u011fi\u015ftirilmeden, i\u00e7eriklerin boyutlar\u0131 ve yerle\u015fimleri de\u011fi\u015ftirilerek kullan\u0131labilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Kriter dok\u00fcman\u0131ndaki her madde her ekipmanda aran\u0131r m\u0131?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Dok\u00fcman\u0131n notuna g\u00f6re kriterler ekipman\u0131n kullan\u0131m yeri, amac\u0131, tipi ve modeline g\u00f6re de\u011fi\u015febilir; kriterin o ekipmanda aran\u0131p aranmayaca\u011f\u0131na at\u0131f yap\u0131lan mevzuat ve standart maddelerine bak\u0131larak karar verilir.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Ministry&#039;s mandatory ZPKR04 periodic inspection report format and ZPKK04 criteria: what is inspected, limit values, report sections.<\/p>","protected":false},"author":1,"featured_media":2568,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","slim_seo":{"title":"Fire Detection and Alarm Systems Periodic Inspection Report (ZPKR04) and Criteria","description":"Periodic inspection of Fire Detection and Warning Systems: Ministry's mandatory ZPKR04 report format and ZPKK04 criteria, measurements and limit values."},"_slim_seo_primary_term_category":0,"_slim_seo_primary_term_post_tag":0,"footnotes":""},"categories":[37],"tags":[],"class_list":["post-6431","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-periyodik-kontrol-rehberi"],"acf":[],"taxonomy_info":{"category":[{"value":37,"label":"Periyodik Kontrol Rehberi"}]},"featured_image_src_large":["https:\/\/aesinn.com\/wp-content\/uploads\/aes-thumbnail.png",768,768,false],"author_info":{"display_name":"Emre Metin","author_link":"https:\/\/aesinn.com\/en\/author\/yonetim\/"},"comment_info":"","category_info":[{"term_id":37,"name":"Periyodik Kontrol Rehberi","slug":"periyodik-kontrol-rehberi","term_group":0,"term_taxonomy_id":37,"taxonomy":"category","description":"Periyodik kontrol ve muayene hakk\u0131nda pratik rehberler: yasal s\u00fcreler, kontrol s\u0131kl\u0131\u011f\u0131, kurulu\u015f se\u00e7imi.","parent":0,"count":21,"filter":"raw","cat_ID":37,"category_count":21,"category_description":"Periyodik kontrol ve muayene hakk\u0131nda pratik rehberler: yasal s\u00fcreler, kontrol s\u0131kl\u0131\u011f\u0131, kurulu\u015f se\u00e7imi.","cat_name":"Periyodik Kontrol Rehberi","category_nicename":"periyodik-kontrol-rehberi","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/posts\/6431","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/comments?post=6431"}],"version-history":[{"count":0,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/posts\/6431\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media\/2568"}],"wp:attachment":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media?parent=6431"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/categories?post=6431"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/tags?post=6431"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}