{"id":6466,"date":"2026-10-27T12:01:37","date_gmt":"2026-10-27T09:01:37","guid":{"rendered":"https:\/\/aesinn.com\/elektrik-sistem-analizi\/ark-flash\/tersanelerde-ark-flash-analizi\/"},"modified":"2026-10-27T13:12:27","modified_gmt":"2026-10-27T10:12:27","slug":"tersanelerde-ark-flash-analizi","status":"publish","type":"page","link":"https:\/\/aesinn.com\/en\/elektrik-sistem-analizi\/ark-flash\/tersanelerde-ark-flash-analizi\/","title":{"rendered":"Arc Flash Analysis in Shipyards"},"content":{"rendered":"<p class=\"wp-block-paragraph\">Electrical distribution in shipyards consists of permanent installations as well as temporary panels and source distribution that change location as the ship progresses. The numerous panels, multiple sites, and constantly changing layouts make both the scope and up-to-date maintenance of arc flash work challenging.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Critical points in the shipyard<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Main distribution and transformer substations<\/li><li>Dry docks, quays and slipways<\/li><li>Distribution panels and field sockets that power welding machines.<\/li><li>Temporary construction site signs<\/li><li>Generators and transfer panels<\/li><li>24V and 48V DC control panels<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Calculation approach<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">IEEE 1584-2018 defines incident energy calculations for three-phase AC systems at voltages between 208 V and 15 kV and frequencies of 50\/60 Hz. Single-phase and DC systems are not included in the model; the standard only refers to methods in the literature (Ammerman, Das, Doan, Klement) for DC (clauses 4.11 and 4.12). In shipyards, recurring field outlets and temporary switchboards are grouped as type switchboards. Since the supply distance may change when the location of temporary switchboards changes, the report must state under what conditions the label remains valid.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Very low voltage (24 V or 48 V) DC control panels are inspected on-site. Arc flash calculations are generally meaningless for purely low-voltage DC panels without an AC input or battery compartment; panels with an AC input or battery compartment are considered. This decision cannot be made without on-site inspection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Data required for shipyard work<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Single line diagram and transformer data for each site.<\/li><li>Types and numbers of power supply distribution and field socket panels.<\/li><li>Power supply arrangement of temporary panels<\/li><li>Generator and transfer panel data<\/li><li>Protective device settings<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Reducing incident energy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The calculation results are used not only for selecting PPE but also for reducing risk at its source. The report provides panel-specific recommendations; commonly applied methods include:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Reconfiguring protection settings to take incident energy into account.<\/li><li>Fast-trip (maintenance mode) settings enabled during maintenance.<\/li><li>Arc detection relays (light and current sensing)<\/li><li>Remote switching and remote racking of withdrawable breakers.<\/li><li>Temporary switchboards have current limiting fuses and a standard power supply system.<\/li><\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">De-energized work always comes first; energized work is permitted only when justified and under an energized electrical work permit.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The scope of AES Innovation<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">We conduct arc flash analysis end-to-end, including data collection, modeling, incident energy calculation, reporting, and labeling. Reports can be prepared in Turkish, English, or bilingually. In shipyards with multiple yards, all yards can be covered in a single study. For general process and pricing factors, please contact us. <a href=\"https:\/\/aesinn.com\/en\/elektrik-sistem-analizi\/ark-flash\/\">arc flash analysis and labeling<\/a> You can check out our page.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/wa.me\/905303237068?text=Merhaba%2C%20ark%20flash%20analizi%20i%C3%A7in%20pano%20listemizi%20g%C3%B6ndermek%20istiyorum.\">Send Your Panel List via WhatsApp<\/a><\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">How are labels prepared for temporary panels?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Temporary panels are grouped according to their supply pattern and labeled according to the most unfavorable supply condition; the label needs to be re-evaluated if the supply pattern changes.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Are 24 V DC panels charged for?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Pure low-voltage DC switchgear is tested on-site and usually requires no calculations; this will be specified separately in the offer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Can multiple shipyard sites be included in a single report?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Yes. The sites are modeled in a single study; the report is segmented by site.<\/p>","protected":false},"excerpt":{"rendered":"<p>Tersanelerde elektrik da\u011f\u0131t\u0131m\u0131, kal\u0131c\u0131 tesislerin yan\u0131nda gemi ilerledik\u00e7e yeri de\u011fi\u015fen ge\u00e7ici panolar ve kaynak da\u011f\u0131t\u0131m\u0131ndan olu\u015fur. \u00c7ok say\u0131da pano, birden fazla saha ve s\u00fcrekli de\u011fi\u015fen yerle\u015fim, ark flash \u00e7al\u0131\u015fmas\u0131n\u0131n hem kapsam\u0131n\u0131 hem de g\u00fcncel tutulmas\u0131n\u0131 zorla\u015ft\u0131r\u0131r. Tersanede kritik noktalar Ana da\u011f\u0131t\u0131m ve trafo merkezleri Kuru havuz, r\u0131ht\u0131m ve k\u0131zak panolar\u0131 Kaynak makinelerini besleyen da\u011f\u0131t\u0131m panolar\u0131&#8230;<\/p>","protected":false},"author":1,"featured_media":2538,"parent":2239,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","slim_seo":{"title":"Arc Flash Analysis and Labeling in Shipyards | AES","description":"Arc flash analysis in shipyards: incident energy and labeling for main distribution, dry dock and quay panels, source distribution and temporary panels."},"_pplb_hide_from_list":false,"footnotes":""},"class_list":["post-6466","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"taxonomy_info":[],"featured_image_src_large":["https:\/\/aesinn.com\/wp-content\/uploads\/ark-flash-analizi-aes.jpg",1024,1024,false],"author_info":{"display_name":"Emre Metin","author_link":"https:\/\/aesinn.com\/en\/author\/yonetim\/"},"comment_info":"","_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6466","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/comments?post=6466"}],"version-history":[{"count":1,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6466\/revisions"}],"predecessor-version":[{"id":6480,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6466\/revisions\/6480"}],"up":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/2239"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media\/2538"}],"wp:attachment":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media?parent=6466"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}