{"id":6169,"date":"2026-09-20T20:57:38","date_gmt":"2026-09-20T17:57:38","guid":{"rendered":"https:\/\/aesinn.com\/muayene-periyodik-kontrol\/mekanik-ekipman-muayeneleri\/iso-8573-basincli-hava-kalite-siniflari-ve-kirlilik-olcumu-bilgilendirme\/"},"modified":"2026-09-20T21:07:48","modified_gmt":"2026-09-20T18:07:48","slug":"iso-8573-basincli-hava-kalite-siniflari-ve-kirlilik-olcumu-bilgilendirme","status":"publish","type":"page","link":"https:\/\/aesinn.com\/en\/muayene-periyodik-kontrol\/mekanik-ekipman-muayeneleri\/iso-8573-basincli-hava-kalite-siniflari-ve-kirlilik-olcumu-bilgilendirme\/","title":{"rendered":"ISO 8573 \u2014 Compressed Air Quality Classes and Pollution Measurement: Information"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Bas\u0131n\u00e7l\u0131 Hava Neden &#8216;Temiz&#8217; Olmal\u0131?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bas\u0131n\u00e7l\u0131 hava, \u00fcretimde motor g\u00fcc\u00fc, ta\u015f\u0131ma, dolum, \u00fcfleme, kurutma ve ambalajlama gibi \u00e7ok say\u0131da proseste kullan\u0131lan bir enerji ta\u015f\u0131y\u0131c\u0131s\u0131d\u0131r. Ancak bu havan\u0131n \u00f6nemli bir k\u0131sm\u0131, do\u011frudan veya dolayl\u0131 olarak \u00fcr\u00fcnle, ambalajla ya da proses y\u00fczeyleriyle temas eder. Bu temas ger\u00e7ekle\u015fti\u011fi anda, havadaki her t\u00fcrl\u00fc kirletici bir kontaminasyon kayna\u011f\u0131na d\u00f6n\u00fc\u015f\u00fcr.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Atmosferden emilen hava; toz, aerosol, su buhar\u0131 ve mikroorganizma i\u00e7erir. Kompres\u00f6r bu havay\u0131 s\u0131k\u0131\u015ft\u0131r\u0131rken kirleticileri de yo\u011funla\u015ft\u0131r\u0131r; ayr\u0131ca kompres\u00f6r ya\u011f\u0131, a\u015f\u0131nma partik\u00fclleri ve borulardaki pas\/tortu da sisteme kar\u0131\u015fabilir. Sonu\u00e7 olarak i\u015flenmemi\u015f bas\u0131n\u00e7l\u0131 hava, \u00fcr\u00fcne temas etmesi halinde ciddi bir kirlilik riski ta\u015f\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu nedenle bas\u0131n\u00e7l\u0131 hava kalitesinin nesnel, \u00f6l\u00e7\u00fclebilir ve uluslararas\u0131 kabul g\u00f6rm\u00fc\u015f bir \u00e7er\u00e7eveyle tan\u0131mlanmas\u0131 gerekir. ISO 8573 serisi tam olarak bu ihtiyac\u0131 kar\u015f\u0131lar. Bu i\u00e7erik, ISO 8573 \u00e7er\u00e7evesini \u00fcreticiye tan\u0131tmak amac\u0131yla haz\u0131rlanm\u0131\u015f bir bilgilendirme \u00e7al\u0131\u015fmas\u0131d\u0131r.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>\u00dcr\u00fcne, ambalaja veya proses y\u00fczeyine temas eden hava = potansiyel kontaminasyon<\/li>\n\n\n<li>S\u0131k\u0131\u015ft\u0131rma, atmosferdeki kirleticileri yo\u011funla\u015ft\u0131r\u0131r<\/li>\n\n\n<li>Kompres\u00f6r ya\u011f\u0131, a\u015f\u0131nma partik\u00fclleri ve boru tortusu ek kaynaklard\u0131r<\/li>\n\n\n<li>Kalite, \u00f6l\u00e7\u00fclebilir s\u0131n\u0131flarla tan\u0131mlanmad\u0131k\u00e7a y\u00f6netilemez<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">ISO 8573 Serisinin Yap\u0131s\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573, tek bir belge de\u011fil, birbirini tamamlayan bir standart serisidir. Serinin temel belgesi olan ISO 8573-1, bas\u0131n\u00e7l\u0131 havadaki kirleticileri tan\u0131mlar ve her kirletici i\u00e7in safl\u0131k (kalite) s\u0131n\u0131flar\u0131n\u0131 belirler. Di\u011fer b\u00f6l\u00fcmler ise bu s\u0131n\u0131flar\u0131n sahada nas\u0131l \u00f6l\u00e7\u00fclece\u011fini, yani \u00f6l\u00e7\u00fcm ve numune alma y\u00f6ntemlerini tarif eder.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6l\u00e7\u00fcm b\u00f6l\u00fcmleri kirletici t\u00fcr\u00fcne g\u00f6re ayr\u0131lm\u0131\u015ft\u0131r. B\u00f6ylece bir s\u0131n\u0131f iddias\u0131 yaln\u0131zca bir hedef de\u011fil, tan\u0131ml\u0131 bir y\u00f6nteme dayal\u0131 olarak do\u011frulanabilir bir sonu\u00e7 h\u00e2line gelir. Serinin bu yap\u0131s\u0131, &#8216;kaliteyi tan\u0131mlama&#8217; ile &#8216;kaliteyi \u00f6l\u00e7me&#8217; i\u015flevlerini birbirinden ay\u0131r\u0131r.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>ISO 8573-1: Kirleticiler ve safl\u0131k s\u0131n\u0131flar\u0131 (\u00e7er\u00e7evenin temeli)<\/li>\n\n\n<li>ISO 8573-2: Ya\u011f aerosol\u00fc i\u00e7eri\u011fi \u00f6l\u00e7\u00fcm y\u00f6ntemi<\/li>\n\n\n<li>ISO 8573-3: Nem\/su buhar\u0131 i\u00e7eri\u011fi \u00f6l\u00e7\u00fcm y\u00f6ntemi<\/li>\n\n\n<li>ISO 8573-4: Kat\u0131 partik\u00fcl i\u00e7eri\u011fi \u00f6l\u00e7\u00fcm y\u00f6ntemi<\/li>\n\n\n<li>ISO 8573-5: Ya\u011f buhar\u0131 ve organik solvent i\u00e7eri\u011fi \u00f6l\u00e7\u00fcm y\u00f6ntemi<\/li>\n\n\n<li>ISO 8573-6: Gaz halindeki kirleticilerin \u00f6l\u00e7\u00fcm\u00fc<\/li>\n\n\n<li>ISO 8573-7: Canl\u0131 (viable) mikrobiyolojik kirletici \u00f6l\u00e7\u00fcm\u00fc<\/li>\n\n\n<li>ISO 8573-8: K\u00fctle konsantrasyonuna g\u00f6re kat\u0131 partik\u00fcl \u00f6l\u00e7\u00fcm\u00fc<\/li>\n\n\n<li>ISO 8573-9: S\u0131v\u0131 su i\u00e7eri\u011finin \u00f6l\u00e7\u00fcm\u00fc<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u00dc\u00e7 Ana Kirletici: Partik\u00fcl, Nem ve Ya\u011f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573-1, bas\u0131n\u00e7l\u0131 hava kalitesini \u00fc\u00e7 ana kirletici \u00fczerinden ele al\u0131r: kat\u0131 partik\u00fcller, su (nem) ve ya\u011f. Bu \u00fc\u00e7 kirletici, farkl\u0131 fiziksel formlarda (kat\u0131, s\u0131v\u0131, buhar, aerosol) bulunabildi\u011fi i\u00e7in her biri kendi i\u00e7inde ayr\u0131 bir \u00f6l\u00e7ek \u00fczerinde de\u011ferlendirilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Kat\u0131 partik\u00fcller; toz, pas, a\u015f\u0131nma \u00fcr\u00fcnleri ve d\u0131\u015f ortamdan gelen tanecikleri kapsar ve valfleri, nozullar\u0131 ve hassas y\u00fczeyleri etkileyebilir. Su hem korozyon ve donma riski hem de mikrobiyal \u00fcreme a\u00e7\u0131s\u0131ndan kritiktir. Ya\u011f ise s\u0131v\u0131, aerosol ve buhar formlar\u0131nda bulunabilir; g\u0131da, ila\u00e7 ve elektronik gibi hassas proseslerde kabul edilebilirli\u011fi en d\u00fc\u015f\u00fck kirleticilerden biridir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Standart, bu \u00fc\u00e7 kirleticiyi ayr\u0131 ayr\u0131 s\u0131n\u0131fland\u0131rd\u0131\u011f\u0131 i\u00e7in bir sistem, \u00f6rne\u011fin partik\u00fcl a\u00e7\u0131s\u0131ndan \u00e7ok temiz s\u0131n\u0131fta iken ya\u011f a\u00e7\u0131s\u0131ndan daha d\u00fc\u015f\u00fck bir s\u0131n\u0131fta olabilir. Bu yakla\u015f\u0131m, her prosesin kendi kritik kirleticisine odaklanmas\u0131na imk\u00e2n verir.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Kat\u0131 partik\u00fcl: toz, pas, a\u015f\u0131nma ve d\u0131\u015f tanecikler<\/li>\n\n\n<li>Su\/nem: korozyon, donma ve mikrobiyal \u00fcreme riski<\/li>\n\n\n<li>Ya\u011f: s\u0131v\u0131, aerosol ve buhar formlar\u0131 ayr\u0131 ayr\u0131 \u00f6nemlidir<\/li>\n\n\n<li>Her kirletici ayr\u0131 s\u0131n\u0131fland\u0131r\u0131l\u0131r; genel bir &#8216;tek not&#8217; verilmez<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Safl\u0131k S\u0131n\u0131f\u0131 Mant\u0131\u011f\u0131 (Class 0 \u2013 Class X)<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573-1&#8217;de her kirletici i\u00e7in, en kat\u0131 olandan en gev\u015fek olana do\u011fru numaraland\u0131r\u0131lm\u0131\u015f safl\u0131k s\u0131n\u0131flar\u0131 tan\u0131mlan\u0131r. Genel mant\u0131k \u015fudur: s\u0131n\u0131f numaras\u0131 k\u00fc\u00e7\u00fcld\u00fck\u00e7e izin verilen kirletici miktar\u0131 azal\u0131r, yani hava daha temizdir. Partik\u00fcl i\u00e7in ek olarak, partik\u00fcllerin boyut aral\u0131klar\u0131na g\u00f6re izin verilen say\u0131s\u0131 da dikkate al\u0131n\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Serinin en kat\u0131 basama\u011f\u0131 olarak an\u0131lan Class 0, sabit bir say\u0131sal limit de\u011fildir; kullan\u0131c\u0131n\u0131n veya ekipman tedarik\u00e7isinin, ilgili s\u0131n\u0131ftan daha iyi bir performans\u0131 yaz\u0131l\u0131 bir teknik \u015fartname ile tan\u0131mlamas\u0131n\u0131 ve g\u00f6stermesini gerektirir. Bu nedenle &#8216;Class 0&#8217; ifadesi, arkas\u0131nda belgelenmi\u015f bir hedef ve \u00f6l\u00e7\u00fcm olmadan tek ba\u015f\u0131na anlam ta\u015f\u0131maz.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bir kalite hedefi genellikle \u00fc\u00e7 rakamla, yani s\u0131ras\u0131yla partik\u00fcl, su ve ya\u011f s\u0131n\u0131flar\u0131yla birlikte ifade edilir. Bu i\u00e7erikte kas\u0131tl\u0131 olarak kesin s\u0131n\u0131f-limit say\u0131lar\u0131 verilmemektedir; ama\u00e7 s\u0131n\u0131f mant\u0131\u011f\u0131n\u0131 aktarmakt\u0131r. Belirli bir uygulamaya kar\u015f\u0131l\u0131k gelen say\u0131sal s\u0131n\u0131f de\u011ferleri, standard\u0131n g\u00fcncel metninden ve yetkili m\u00fchendis de\u011ferlendirmesinden do\u011frulanmal\u0131d\u0131r.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>K\u00fc\u00e7\u00fck s\u0131n\u0131f numaras\u0131 = daha az kirletici = daha temiz hava<\/li>\n\n\n<li>Partik\u00fclde boyut aral\u0131\u011f\u0131 ba\u015f\u0131na say\u0131 da dikkate al\u0131n\u0131r<\/li>\n\n\n<li>Class 0: sabit limit de\u011fil, yaz\u0131l\u0131 \u015fartname ile tan\u0131mlanan en kat\u0131 basamak<\/li>\n\n\n<li>Hedef, partik\u00fcl-su-ya\u011f i\u00e7in ayr\u0131 s\u0131n\u0131f de\u011ferleriyle birlikte ifade edilir<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Bas\u0131n\u00e7l\u0131 \u00c7iy Noktas\u0131 (PDP) Kavram\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Nem s\u0131n\u0131flar\u0131n\u0131n merkezinde bas\u0131n\u00e7l\u0131 \u00e7iy noktas\u0131 (Pressure Dew Point, PDP) kavram\u0131 yer al\u0131r. PDP, bas\u0131n\u00e7l\u0131 havan\u0131n kendi \u00e7al\u0131\u015fma bas\u0131nc\u0131 alt\u0131nda suyun yo\u011fu\u015fmaya ba\u015flad\u0131\u011f\u0131 s\u0131cakl\u0131kt\u0131r. PDP ne kadar d\u00fc\u015f\u00fckse, hava o kadar kurudur ve yo\u011fu\u015fma (kondens) riski o kadar azd\u0131r.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PDP&#8217;nin \u00e7al\u0131\u015fma bas\u0131nc\u0131nda tan\u0131mlanmas\u0131 \u00f6nemlidir; \u00e7\u00fcnk\u00fc ayn\u0131 hava atmosfer bas\u0131nc\u0131na geni\u015fledi\u011finde \u00e7iy noktas\u0131 de\u011fi\u015fir. Bu nedenle nem performans\u0131 de\u011ferlendirilirken \u00e7iy noktas\u0131 daima ilgili bas\u0131n\u00e7 ko\u015fuluyla birlikte ele al\u0131nmal\u0131d\u0131r. Donma riski ta\u015f\u0131yan hatlar veya hassas dolum prosesleri i\u00e7in d\u00fc\u015f\u00fck PDP hedefleri belirleyici olabilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573-1&#8217;deki nem s\u0131n\u0131flar\u0131, buhar formundaki su i\u00e7in bu PDP de\u011ferlerine dayan\u0131rken; s\u0131v\u0131 ve aerosol formundaki su ayr\u0131 bi\u00e7imde ele al\u0131n\u0131r. B\u00f6ylece nem, tek bir s\u0131cakl\u0131k de\u011feri de\u011fil, formuna g\u00f6re de\u011ferlendirilen bir kirletici olarak konumlan\u0131r.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>PDP: \u00e7al\u0131\u015fma bas\u0131nc\u0131nda suyun yo\u011fu\u015fmaya ba\u015flad\u0131\u011f\u0131 s\u0131cakl\u0131k<\/li>\n\n\n<li>D\u00fc\u015f\u00fck PDP = daha kuru hava = daha az yo\u011fu\u015fma riski<\/li>\n\n\n<li>\u00c7iy noktas\u0131 daima ilgili bas\u0131n\u00e7 ko\u015fuluyla birlikte okunmal\u0131<\/li>\n\n\n<li>Buhar h\u00e2lindeki su PDP ile, s\u0131v\u0131\/aerosol su ayr\u0131ca de\u011ferlendirilir<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u00d6l\u00e7\u00fcm Noktalar\u0131 ve Numune Alma<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bir safl\u0131k s\u0131n\u0131f\u0131 iddias\u0131, yaln\u0131zca sistemin belirli bir noktas\u0131nda ge\u00e7erlidir. ISO 8573-1, s\u0131n\u0131flar\u0131n sistemdeki konumdan ba\u011f\u0131ms\u0131z olarak tan\u0131mlanabildi\u011fini belirtir; ancak pratikte havan\u0131n kalitesi kompres\u00f6r \u00e7\u0131k\u0131\u015f\u0131, kurutucu sonras\u0131, filtre \u00e7\u0131k\u0131\u015f\u0131 ve kullan\u0131m noktas\u0131 aras\u0131nda \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015fir. Bu y\u00fczden \u00f6l\u00e7\u00fcm\u00fcn nerede yap\u0131ld\u0131\u011f\u0131, sonucu do\u011frudan etkiler.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u00d6l\u00e7\u00fcm ve numune alma, ilgili \u00f6l\u00e7\u00fcm b\u00f6l\u00fcmlerinde (partik\u00fcl, nem, ya\u011f aerosol\u00fc, ya\u011f buhar\u0131 vb.) tarif edilen y\u00f6ntemlere g\u00f6re yap\u0131l\u0131r. Do\u011fru sonu\u00e7 i\u00e7in numune alma ko\u015fullar\u0131, hatt\u0131n kararl\u0131 rejimde olmas\u0131, uygun ak\u0131\u015f ve temiz numune hatlar\u0131 gibi fakt\u00f6rler kritiktir. Uygun olmayan numune alma, ger\u00e7ek performanstan sapan sonu\u00e7lara yol a\u00e7abilir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Bu nedenle bir hedefin kar\u015f\u0131lan\u0131p kar\u015f\u0131lanmad\u0131\u011f\u0131 de\u011ferlendirilirken; hedeflenen s\u0131n\u0131f, \u00f6l\u00e7\u00fcm noktas\u0131, \u00f6l\u00e7\u00fcm y\u00f6ntemi ve \u00f6l\u00e7\u00fcm ko\u015fullar\u0131 bir b\u00fct\u00fcn olarak ele al\u0131nmal\u0131d\u0131r. \u00d6l\u00e7\u00fcm stratejisinin planlanmas\u0131 ve yorumlanmas\u0131, yetkili m\u00fchendis teknik de\u011ferlendirmesini gerektiren bir konudur.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>Kalite sistemin farkl\u0131 noktalar\u0131nda farkl\u0131d\u0131r: \u00e7\u0131k\u0131\u015f farkl\u0131, kullan\u0131m noktas\u0131 farkl\u0131<\/li>\n\n\n<li>\u00d6l\u00e7\u00fcm y\u00f6ntemi kirletici t\u00fcr\u00fcne g\u00f6re ilgili b\u00f6l\u00fcmde tan\u0131ml\u0131d\u0131r<\/li>\n\n\n<li>Kararl\u0131 rejim, uygun ak\u0131\u015f ve temiz numune hatt\u0131 sonu\u00e7 i\u00e7in kritik<\/li>\n\n\n<li>Hedef, \u00f6l\u00e7\u00fcm noktas\u0131 ve y\u00f6ntem birlikte de\u011ferlendirilmeli<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Hangi Sekt\u00f6rler ve Genel GMP\/G\u0131da G\u00fcvenli\u011fi Beklentileri<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Bas\u0131n\u00e7l\u0131 hava kalitesi, \u00f6zellikle havan\u0131n \u00fcr\u00fcne veya ambalaja temas etti\u011fi sekt\u00f6rlerde belirleyicidir. G\u0131da ve i\u00e7ecek \u00fcretiminde \u00fcr\u00fcnle temas eden hava i\u00e7in genellikle ya\u011f ve mikrobiyolojik a\u00e7\u0131dan kat\u0131 beklentiler \u00f6ne \u00e7\u0131kar. \u0130la\u00e7 ve GMP kapsam\u0131ndaki \u00fcretimde, temas eden havan\u0131n tan\u0131ml\u0131 ve izlenebilir bir kalite hedefine g\u00f6re y\u00f6netilmesi beklenir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Elektronik ve yar\u0131 iletken \u00fcretiminde partik\u00fcl ve nem kontrol\u00fc, hassas bile\u015fenlerin korunmas\u0131 a\u00e7\u0131s\u0131ndan kritiktir. Boya ve y\u00fczey i\u015flem uygulamalar\u0131nda ya\u011f ve su, y\u00fczey kusurlar\u0131n\u0131n ba\u015fl\u0131ca nedenlerindendir. Medikal uygulamalarda ise havan\u0131n safl\u0131\u011f\u0131 do\u011frudan g\u00fcvenlikle ili\u015fkilidir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Genel \u00e7er\u00e7evede, g\u0131da g\u00fcvenli\u011fi ve GMP yakla\u015f\u0131mlar\u0131; risk de\u011ferlendirmesi, temas eden bas\u0131n\u00e7l\u0131 hava i\u00e7in tan\u0131ml\u0131 kalite hedefleri ve d\u00fczenli do\u011frulama beklentisiyle ISO 8573&#8217;\u00fcn sa\u011flad\u0131\u011f\u0131 \u00f6l\u00e7\u00fclebilir s\u0131n\u0131f mant\u0131\u011f\u0131yla uyumludur. Belirli bir tesis i\u00e7in hangi s\u0131n\u0131flar\u0131n gerekti\u011fi, \u00fcr\u00fcn, proses ve ilgili sekt\u00f6rel gerekliliklere g\u00f6re yetkili m\u00fchendis de\u011ferlendirmesiyle belirlenmelidir.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>G\u0131da-i\u00e7ecek: ya\u011f ve mikrobiyolojik kontrol \u00f6nceli\u011fi<\/li>\n\n\n<li>\u0130la\u00e7\/GMP: tan\u0131ml\u0131, izlenebilir kalite hedefi beklentisi<\/li>\n\n\n<li>Elektronik\/yar\u0131 iletken: partik\u00fcl ve nem kritik<\/li>\n\n\n<li>Boya ve medikal: ya\u011f, su ve safl\u0131k do\u011frudan kaliteyi\/g\u00fcvenli\u011fi etkiler<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Bilgilendirme Notu ve AES&#8217;in Kapsam\u0131<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">AES (aesinn.com), T\u00dcRKAK akrediteli A tipi muayene kurulu\u015fu olarak faaliyet g\u00f6stermektedir. AES&#8217;in akreditasyon kapsam\u0131 &#8216;6.1 Elektrik Tesisat\u0131&#8217; alan\u0131d\u0131r. Bu i\u00e7erik, bas\u0131n\u00e7l\u0131 hava kalitesi ve ISO 8573 \u00e7er\u00e7evesini tan\u0131tmaya y\u00f6nelik bir bilgilendirme \u00e7al\u0131\u015fmas\u0131 olup, AES&#8217;in akreditasyon kapsam\u0131n\u0131n bir beyan\u0131 de\u011fildir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AES bu kapsamda akredite muayene\/belgelendirme kurulu\u015fu DE\u011e\u0130LD\u0130R. \u0130\u00e7erik bilgilendirme ama\u00e7l\u0131d\u0131r ve yetkili m\u00fchendis teknik de\u011ferlendirmesi \u00e7er\u00e7evesindedir.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573 kapsam\u0131ndaki s\u0131n\u0131f hedeflerinin belirlenmesi, \u00f6l\u00e7\u00fcm y\u00f6ntemlerinin se\u00e7imi ve sonu\u00e7lar\u0131n yorumlanmas\u0131; standard\u0131n g\u00fcncel metnine ve konuya ili\u015fkin yetkili m\u00fchendis de\u011ferlendirmesine dayanmal\u0131d\u0131r. Bu i\u00e7erikte yer alan bilgiler, yerinde yap\u0131lacak teknik de\u011ferlendirmenin yerine ge\u00e7mez.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li>AES: T\u00dcRKAK akrediteli A tipi muayene kurulu\u015fu<\/li>\n\n\n<li>Akreditasyon kapsam\u0131: &#8216;6.1 Elektrik Tesisat\u0131&#8217;<\/li>\n\n\n<li>Bu i\u00e7erik bilgilendirme ama\u00e7l\u0131d\u0131r, kapsam beyan\u0131 de\u011fildir<\/li>\n\n\n<li>S\u0131n\u0131f ve \u00f6l\u00e7\u00fcm kararlar\u0131 yetkili m\u00fchendis de\u011ferlendirmesi ister<\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Related Services<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n\n<li><a href=\"https:\/\/aesinn.com\/en\/muayene-periyodik-kontrol\/mekanik-ekipman-muayeneleri\/kompresor-hava-tanklari-periyodik-kontrol\/\">Periodic Inspection of Compressor Air Tanks<\/a><\/li>\n\n\n<li><a href=\"https:\/\/aesinn.com\/en\/test-ve-olcum-hizmetleri\/iso-4406-iso-11171-iso-16232-hidrolik-ve-akiskan-sistemlerde-partikul-temizlik-sinifi-ve-olcumu\/\">ISO 4406 Hidrolik Ak\u0131\u015fkan Partik\u00fcl Temizlik S\u0131n\u0131f\u0131<\/a><\/li>\n\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">ISO 8573 tam olarak neyi tan\u0131mlar?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">ISO 8573, bas\u0131n\u00e7l\u0131 havadaki kirleticileri ve bunlara kar\u015f\u0131l\u0131k gelen safl\u0131k s\u0131n\u0131flar\u0131n\u0131 tan\u0131mlayan bir standart serisidir. Temel b\u00f6l\u00fcm olan ISO 8573-1 kirleticileri ve s\u0131n\u0131flar\u0131 belirlerken, di\u011fer b\u00f6l\u00fcmler (8573-2 ile 8573-9) bu kirleticilerin nas\u0131l \u00f6l\u00e7\u00fclece\u011fini tarif eder. Bu bilgilendirme metni, \u00e7er\u00e7eveyi tan\u0131tmay\u0131 ama\u00e7lar; kesin s\u0131n\u0131f-limit de\u011ferleri standard\u0131n g\u00fcncel metninden do\u011frulanmal\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Class 0 &#8216;s\u0131f\u0131r kirlilik&#8217; anlam\u0131na m\u0131 gelir?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Hay\u0131r. Class 0, s\u0131f\u0131r kirlilik veya sabit bir say\u0131sal limit anlam\u0131na gelmez. En kat\u0131 basamak olarak, kullan\u0131c\u0131n\u0131n veya ekipman tedarik\u00e7isinin ilgili s\u0131n\u0131ftan daha iyi bir performans\u0131 yaz\u0131l\u0131 bir teknik \u015fartname ile tan\u0131mlamas\u0131n\u0131 ve g\u00f6stermesini gerektirir. Bu nedenle bir &#8216;Class 0&#8217; iddias\u0131, arkas\u0131ndaki yaz\u0131l\u0131 \u015fartname ve \u00f6l\u00e7\u00fcmle birlikte de\u011ferlendirilmelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Bas\u0131n\u00e7l\u0131 \u00e7iy noktas\u0131 (PDP) neden \u00f6nemlidir?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">PDP, bas\u0131n\u00e7l\u0131 havan\u0131n \u00e7al\u0131\u015fma bas\u0131nc\u0131 alt\u0131nda suyun yo\u011fu\u015fmaya ba\u015flad\u0131\u011f\u0131 s\u0131cakl\u0131kt\u0131r ve nem s\u0131n\u0131flar\u0131n\u0131n temelini olu\u015fturur. D\u00fc\u015f\u00fck PDP daha kuru hava ve daha az yo\u011fu\u015fma riski demektir. \u00c7iy noktas\u0131 bas\u0131nca ba\u011fl\u0131 olarak de\u011fi\u015fti\u011fi i\u00e7in daima ilgili bas\u0131n\u00e7 ko\u015fuluyla birlikte de\u011ferlendirilmelidir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Neden bir sistem i\u00e7in tek bir kalite rakam\u0131 yerine \u00fc\u00e7 ayr\u0131 s\u0131n\u0131f konu\u015fuluyor?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u00c7\u00fcnk\u00fc ISO 8573-1, \u00fc\u00e7 ana kirleticiyi (kat\u0131 partik\u00fcl, su\/nem ve ya\u011f) ayr\u0131 ayr\u0131 s\u0131n\u0131fland\u0131r\u0131r. Bir sistem partik\u00fcl a\u00e7\u0131s\u0131ndan \u00e7ok temiz s\u0131n\u0131fta iken ya\u011f a\u00e7\u0131s\u0131ndan daha d\u00fc\u015f\u00fck bir s\u0131n\u0131fta olabilir. Bu y\u00fczden kalite hedefi genellikle partik\u00fcl, su ve ya\u011f i\u00e7in ayr\u0131 s\u0131n\u0131f de\u011ferleriyle birlikte ifade edilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u00d6l\u00e7\u00fcm\u00fcn yap\u0131ld\u0131\u011f\u0131 nokta sonucu etkiler mi?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Evet. Havan\u0131n kalitesi kompres\u00f6r \u00e7\u0131k\u0131\u015f\u0131, kurutucu ve filtre sonras\u0131 ile kullan\u0131m noktas\u0131 aras\u0131nda \u00f6nemli \u00f6l\u00e7\u00fcde de\u011fi\u015fir. Bu nedenle bir s\u0131n\u0131f iddias\u0131, \u00f6l\u00e7\u00fcm\u00fcn yap\u0131ld\u0131\u011f\u0131 nokta, kullan\u0131lan \u00f6l\u00e7\u00fcm y\u00f6ntemi ve \u00f6l\u00e7\u00fcm ko\u015fullar\u0131yla birlikte anlam ta\u015f\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">AES bu kapsamda \u00f6l\u00e7\u00fcm veya belgelendirme yap\u0131yor mu?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">AES bu kapsamda akredite muayene\/belgelendirme kurulu\u015fu de\u011fildir. AES&#8217;in T\u00dcRKAK akreditasyon kapsam\u0131 &#8216;6.1 Elektrik Tesisat\u0131&#8217; alan\u0131d\u0131r. Bu i\u00e7erik bilgilendirme ama\u00e7l\u0131d\u0131r ve yetkili m\u00fchendis teknik de\u011ferlendirmesi \u00e7er\u00e7evesindedir.<\/p>","protected":false},"excerpt":{"rendered":"<p>\u00dcretim prosesine temas eden bas\u0131n\u00e7l\u0131 hava neden &#8216;temiz&#8217; olmal\u0131? ISO 8573 serisi kirletici s\u0131n\u0131flar\u0131n\u0131 (partik\u00fcl, nem, ya\u011f) ve safl\u0131k s\u0131n\u0131f\u0131 mant\u0131\u011f\u0131n\u0131 nas\u0131l tan\u0131mlar? \u00d6l\u00e7\u00fcm y\u00f6ntemleri, bas\u0131n\u00e7l\u0131 \u00e7iy noktas\u0131 ve sekt\u00f6rel beklentiler \u00fczerine bilgilendirme.<\/p>","protected":false},"author":1,"featured_media":6174,"parent":4099,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","slim_seo":{"title":"ISO 8573 Compressed Air Quality Classes | Information","description":"ISO 8573 compressed air quality classes, solid particle-moisture-oil contaminants, purity class logic and compressed air dew point (PDP) information."},"_pplb_hide_from_list":false,"footnotes":""},"class_list":["post-6169","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"taxonomy_info":[],"featured_image_src_large":["https:\/\/aesinn.com\/wp-content\/uploads\/iso8573-aes-kart-1024x1024.png",1024,1024,true],"author_info":{"display_name":"Emre Metin","author_link":"https:\/\/aesinn.com\/en\/author\/yonetim\/"},"comment_info":"","_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6169","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/comments?post=6169"}],"version-history":[{"count":2,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6169\/revisions"}],"predecessor-version":[{"id":6178,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/6169\/revisions\/6178"}],"up":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4099"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media\/6174"}],"wp:attachment":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media?parent=6169"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}