{"id":4685,"date":"2026-05-31T02:02:32","date_gmt":"2026-05-30T23:02:32","guid":{"rendered":"https:\/\/aesinn.com\/?page_id=4685"},"modified":"2026-05-31T02:46:52","modified_gmt":"2026-05-30T23:46:52","slug":"gazli-yangin-sondurme-sistemleri-fm200-co2-kontrolu","status":"publish","type":"page","link":"https:\/\/aesinn.com\/en\/yangin-tesisatlari-muayeneleri\/gazli-yangin-sondurme-sistemleri-fm200-co2-kontrolu\/","title":{"rendered":"Inspection of Gas Fire Suppression Systems (FM200, CO2)"},"content":{"rendered":"<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Short answer:<\/strong> Gazl\u0131 yang\u0131n s\u00f6nd\u00fcrme sistemleri (FM200, CO2, inert gaz), su ile m\u00fcdahale edilemeyen hassas alanlar\u0131 (veri merkezi, pano odas\u0131, ar\u015fiv) s\u00f6nd\u00fcren sabit sistemlerdir. Gaz miktar\u0131, tetikleme ve bo\u015falma TS ISO 14520 \/ TS EN ve BYKHY \u00e7er\u00e7evesinde kontrol edilir.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Gazl\u0131 sistemler; elektronik ekipmana zarar vermeden, saniyeler i\u00e7inde s\u00f6nd\u00fcrme yapar. Eksik gaz miktar\u0131, yanl\u0131\u015f tetikleme veya ka\u00e7ak; sistemin yang\u0131nda yetersiz kalmas\u0131na ya da istenmeyen bo\u015falmaya yol a\u00e7ar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Periyodik kontrol; t\u00fcp bas\u0131n\u00e7lar\u0131n\u0131, tetikleme zincirini ve mahal s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131 do\u011frulayarak sistemin hem etkili hem g\u00fcvenli \u00e7al\u0131\u015fmas\u0131n\u0131 sa\u011flar.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What is checked?<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>T\u00fcp\/silindir bas\u0131nc\u0131 ve gaz miktar\u0131 (tart\u0131m)<\/li><li>Alg\u0131lama-tetikleme paneli ve \u00e7apraz b\u00f6lgeleme<\/li><li>Solenoid, pilot t\u00fcp ve manuel bo\u015faltma istasyonu<\/li><li>Noz\u00fcller, boru hatt\u0131 ve y\u00f6n<\/li><li>Mahal s\u0131zd\u0131rmazl\u0131\u011f\u0131 (door fan \/ oda b\u00fct\u00fcnl\u00fck testi)<\/li><li>Geciktirme, uyar\u0131 ve havaland\u0131rma kilitleme<\/li><li>Bas\u0131n\u00e7 tahliye damperi ve emniyet<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Y\u00f6ntem ve Mahal B\u00fct\u00fcnl\u00fck Testi<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Muayene; t\u00fcplerin tart\u0131larak gaz miktar\u0131n\u0131n do\u011frulanmas\u0131, tetikleme zincirinin (alg\u0131lama\u2192panel\u2192solenoid) test edilmesi ve gerekti\u011finde <strong>oda b\u00fct\u00fcnl\u00fck testini (door fan test)<\/strong> kapsar. <strong>TS ISO 14520<\/strong>, temiz gazl\u0131 sistemler i\u00e7in tasar\u0131m ve bo\u015falma konsantrasyonunu belirler. Bo\u015falan gaz\u0131n gerekli s\u00fcre mahalde kalmas\u0131 i\u00e7in odan\u0131n s\u0131zd\u0131rmazl\u0131\u011f\u0131 kritiktir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Legal Basis and Period<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gazl\u0131 s\u00f6nd\u00fcrme sistemleri BYKHY ve ilgili TS ISO\/TS EN standartlar\u0131 kapsam\u0131nda d\u00fczenli kontrol edilmeli ve yetkili ki\u015filerce raporlanmal\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Nonconformities<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Tart\u0131mda gaz kayb\u0131 tespit edilen t\u00fcpler<\/li><li>Test edilmemi\u015f\/ar\u0131zal\u0131 tetikleme zinciri<\/li><li>Mahal s\u0131zd\u0131rmazl\u0131\u011f\u0131n\u0131n bozulmas\u0131 (yeni delik\/kanal)<\/li><li>Devre d\u0131\u015f\u0131 manuel bo\u015faltma veya kilitleme<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Gaz miktar\u0131 nas\u0131l do\u011frulan\u0131r?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Silindirler tart\u0131larak veya bas\u0131n\u00e7 \u00f6l\u00e7\u00fclerek tasar\u0131m dolum de\u011feriyle kar\u015f\u0131la\u015ft\u0131r\u0131l\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Oda b\u00fct\u00fcnl\u00fck testi nedir?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Door fan testiyle mahalin s\u0131zd\u0131rmazl\u0131\u011f\u0131 \u00f6l\u00e7\u00fcl\u00fcr; gaz\u0131n yeterli s\u00fcre kalaca\u011f\u0131 do\u011frulan\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Hangi standart esast\u0131r?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Temiz gazl\u0131 sistemler i\u00e7in TS ISO 14520 ve BYKHY esas al\u0131n\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Yang\u0131n G\u00fcvenli\u011finizi Belgeleyin<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Akredite kontrol i\u00e7in <a href=\"https:\/\/aesinn.com\/en\/yangin-tesisatlari-muayeneleri\/\">Fire Installation Inspections<\/a> Check out our page; <a href=\"https:\/\/aesinn.com\/en\/is-ekipmanlari-periyodik-kontrol-zorunlu-mu\/\">mandatory periodic inspection<\/a> Check our guide.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\"><div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/aesinn.com\/en\/iletisim\/\">Get a free quote \u00bb<\/a><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>K\u0131sa yan\u0131t: Gazl\u0131 yang\u0131n s\u00f6nd\u00fcrme sistemleri (FM200, CO2, inert gaz), su ile m\u00fcdahale edilemeyen hassas alanlar\u0131 (veri merkezi, pano odas\u0131, ar\u015fiv) s\u00f6nd\u00fcren sabit sistemlerdir. Gaz miktar\u0131, tetikleme ve bo\u015falma TS ISO 14520 \/ TS EN ve BYKHY \u00e7er\u00e7evesinde kontrol edilir. Gazl\u0131 sistemler; elektronik ekipmana zarar vermeden, saniyeler i\u00e7inde s\u00f6nd\u00fcrme yapar. Eksik gaz miktar\u0131, yanl\u0131\u015f tetikleme&#8230;<\/p>","protected":false},"author":1,"featured_media":2568,"parent":2371,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","slim_seo":{"title":"Gazl\u0131 Yang\u0131n S\u00f6nd\u00fcrme Sistemleri (FM200, CO2) Kontrol\u00fc - AES Innovation","description":"K\u0131sa yan\u0131t: Gazl\u0131 yang\u0131n s\u00f6nd\u00fcrme sistemleri (FM200, CO2, inert gaz), su ile m\u00fcdahale edilemeyen hassas alanlar\u0131 (veri merkezi, pano odas\u0131, ar\u015fiv) s\u00f6nd\u00fcren sabi"},"_pplb_hide_from_list":false,"footnotes":""},"class_list":["post-4685","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"taxonomy_info":[],"featured_image_src_large":["https:\/\/aesinn.com\/wp-content\/uploads\/aes-thumbnail.png",768,768,false],"author_info":{"display_name":"yonetim","author_link":"https:\/\/aesinn.com\/en\/author\/yonetim\/"},"comment_info":"","_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/comments?post=4685"}],"version-history":[{"count":2,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4685\/revisions"}],"predecessor-version":[{"id":4771,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4685\/revisions\/4771"}],"up":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/2371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media\/2568"}],"wp:attachment":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media?parent=4685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}