{"id":4679,"date":"2026-05-31T02:02:23","date_gmt":"2026-05-30T23:02:23","guid":{"rendered":"https:\/\/aesinn.com\/?page_id=4679"},"modified":"2026-05-31T02:46:44","modified_gmt":"2026-05-30T23:46:44","slug":"yagmurlama-sprinkler-sistemleri-kontrolu","status":"publish","type":"page","link":"https:\/\/aesinn.com\/en\/yangin-tesisatlari-muayeneleri\/yagmurlama-sprinkler-sistemleri-kontrolu\/","title":{"rendered":"Inspection of Sprinkler Systems"},"content":{"rendered":"<blockquote class=\"wp-block-quote is-layout-flow wp-block-quote-is-layout-flow\"><p><strong>Short answer:<\/strong> Ya\u011fmurlama (sprinkler) sistemleri, yang\u0131n\u0131 ba\u015flad\u0131\u011f\u0131 noktada otomatik olarak s\u00f6nd\u00fcren\/kontrol alt\u0131na alan su esasl\u0131 sabit s\u00f6nd\u00fcrme sistemleridir. Pompa, vana, boru \u015febekesi ve sprinkler ba\u015fl\u0131klar\u0131 TS EN 12845 ve BYKHY \u00e7er\u00e7evesinde periyodik kontrol edilir.<\/p><\/blockquote>\n\n\n\n<p class=\"wp-block-paragraph\">Sprinkler sistemi, can ve mal g\u00fcvenli\u011finin en etkili otomatik bariyeridir. Kapal\u0131 bir vana, d\u00fc\u015f\u00fck bas\u0131n\u00e7 veya boyal\u0131\/t\u0131kal\u0131 bir ba\u015fl\u0131k; yang\u0131n an\u0131nda sistemin devreye girmemesine yol a\u00e7ar.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Periyodik kontrol, sistemin ger\u00e7ek bir yang\u0131nda tasarland\u0131\u011f\u0131 debide su verece\u011fini \u00f6nceden do\u011frular ve yasal uygunlu\u011fu belgeler.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">What is checked?<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Sprinkler ba\u015fl\u0131klar\u0131: boya, korozyon, t\u0131kan\u0131kl\u0131k ve y\u00f6n<\/li><li>Ana kontrol ve b\u00f6lge vanalar\u0131n\u0131n a\u00e7\u0131k\/kilitli durumu<\/li><li>Alarm vanas\u0131, ak\u0131\u015f anahtar\u0131 ve test hatt\u0131<\/li><li>Pompa bas\u0131nc\u0131, debi ve otomatik devreye girme<\/li><li>Boru \u015febekesi ask\u0131\/destek ve s\u0131zd\u0131rmazl\u0131k<\/li><li>Su kayna\u011f\u0131 kapasitesi ve yedeklilik<\/li><li>Kuru sistemlerde hava bas\u0131nc\u0131 ve h\u0131zl\u0131 bo\u015faltma<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Method and Standard<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Muayene; g\u00f6rsel muayene ile test hatt\u0131 \u00fczerinden fonksiyon ve ak\u0131\u015f testlerini kapsar. Tasar\u0131m ve bak\u0131m gereksinimleri <strong>TS EN 12845<\/strong> (sabit yang\u0131n s\u00f6nd\u00fcrme \u2013 otomatik sprinkler) ve BYKHY taraf\u0131ndan belirlenir. Alarm vanas\u0131 test edilerek ak\u0131\u015f anahtar\u0131n\u0131n ve sesli alarm\u0131n tetiklenmesi do\u011frulan\u0131r; pompa otomatik bas\u0131n\u00e7 d\u00fc\u015f\u00fcm\u00fcnde devreye al\u0131n\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Legal Basis and Period<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Ya\u011fmurlama sistemleri BYKHY ve ilgili TS EN standartlar\u0131 kapsam\u0131nda d\u00fczenli kontrol edilmeli, kontrol yetkili ki\u015filerce raporlanmal\u0131d\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Common Nonconformities<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Bak\u0131m\/tadilat sonras\u0131 kapal\u0131 unutulan ana vana<\/li><li>Boyanm\u0131\u015f veya korozyona u\u011fram\u0131\u015f sprinkler ba\u015fl\u0131klar\u0131<\/li><li>Otomatik devreye girmeyen yang\u0131n pompas\u0131<\/li><li>T\u0131kal\u0131\/\u00e7al\u0131\u015fmayan ak\u0131\u015f anahtar\u0131 ve alarm<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Frequently Asked Questions<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">Sprinkler sistemi hangi standarda g\u00f6re kontrol edilir?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TS EN 12845 ve BYKHY esas al\u0131n\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">En s\u0131k kar\u015f\u0131la\u015f\u0131lan kusur nedir?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bak\u0131m sonras\u0131 a\u00e7\u0131k kalmas\u0131 gereken ana vanan\u0131n kapal\u0131 unutulmas\u0131d\u0131r.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Pompa testi nas\u0131l yap\u0131l\u0131r?<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Bas\u0131n\u00e7 d\u00fc\u015f\u00fcr\u00fclerek pompan\u0131n otomatik devreye girmesi ve hedef debi\/bas\u0131nc\u0131 sa\u011flamas\u0131 do\u011frulan\u0131r.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Yang\u0131n G\u00fcvenli\u011finizi Belgeleyin<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Akredite yang\u0131n tesisat\u0131 muayenesi i\u00e7in <a href=\"https:\/\/aesinn.com\/en\/yangin-tesisatlari-muayeneleri\/\">Fire Installation Inspections<\/a> Check out our page; <a href=\"https:\/\/aesinn.com\/en\/is-ekipmanlari-periyodik-kontrol-zorunlu-mu\/\">mandatory periodic inspection<\/a> Check our guide.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\"><div class=\"wp-block-button\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/aesinn.com\/en\/iletisim\/\">Get a free quote \u00bb<\/a><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>K\u0131sa yan\u0131t: Ya\u011fmurlama (sprinkler) sistemleri, yang\u0131n\u0131 ba\u015flad\u0131\u011f\u0131 noktada otomatik olarak s\u00f6nd\u00fcren\/kontrol alt\u0131na alan su esasl\u0131 sabit s\u00f6nd\u00fcrme sistemleridir. Pompa, vana, boru \u015febekesi ve sprinkler ba\u015fl\u0131klar\u0131 TS EN 12845 ve BYKHY \u00e7er\u00e7evesinde periyodik kontrol edilir. Sprinkler sistemi, can ve mal g\u00fcvenli\u011finin en etkili otomatik bariyeridir. Kapal\u0131 bir vana, d\u00fc\u015f\u00fck bas\u0131n\u00e7 veya boyal\u0131\/t\u0131kal\u0131 bir ba\u015fl\u0131k; yang\u0131n an\u0131nda&#8230;<\/p>","protected":false},"author":1,"featured_media":2568,"parent":2371,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"_kad_post_classname":"","slim_seo":{"title":"Ya\u011fmurlama (Sprinkler) Sistemleri Kontrol\u00fc - AES Innovation","description":"K\u0131sa yan\u0131t: Ya\u011fmurlama (sprinkler) sistemleri, yang\u0131n\u0131 ba\u015flad\u0131\u011f\u0131 noktada otomatik olarak s\u00f6nd\u00fcren\/kontrol alt\u0131na alan su esasl\u0131 sabit s\u00f6nd\u00fcrme sistemleridir. Po"},"_pplb_hide_from_list":false,"footnotes":""},"class_list":["post-4679","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"taxonomy_info":[],"featured_image_src_large":["https:\/\/aesinn.com\/wp-content\/uploads\/aes-thumbnail.png",768,768,false],"author_info":{"display_name":"yonetim","author_link":"https:\/\/aesinn.com\/en\/author\/yonetim\/"},"comment_info":"","_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4679","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/comments?post=4679"}],"version-history":[{"count":2,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4679\/revisions"}],"predecessor-version":[{"id":4765,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/4679\/revisions\/4765"}],"up":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/pages\/2371"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media\/2568"}],"wp:attachment":[{"href":"https:\/\/aesinn.com\/en\/wp-json\/wp\/v2\/media?parent=4679"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}